Discontinued

1 Port RS232 Serial over IP Ethernet Device Server

Connect to, configure and remotely manage an RS-232 serial device over an IP network

Product ID: NETRS232_1EU

0 stars (0 reviews) |
  • Browser based configuration of network settings, serial port line settings, UART transmit and receive buffer trigger levels and serial port flow control
  • Comes complete with Ether Link Manager software making serial device configuration easy
  • Data transfer rates of up to 115.2 Kb/sec per port

Take your serial peripherals to new lengths. With this one-port Ethernet-to-Remote Serial interface converter, your RS-232 serial devices can be placed anywhere on your TCP/IP Ethernet WAN/LAN and still perform as if they were right beside you. It even works over the Internet!

Even at the longest distances, control of your serial devices will be right at your fingertips: the remote serial ports appear alongside your local serial ports in your Windows device manager.

NETRS232_1 is designed to function seamlessly with your other serial ports for totally transparent operation. Your serial equipment – card scanners, access keypads, bar code scanners, and more – will operate as smoothly as if the serial ports were right inside your computer. For industrial automation, security, Point of Sale, or any time you need reliable, long-range serial communications, the NETRS232_1 delivers superior performance in any environment.

Applications

  • Environmental Control (lighting, temperature, clocks)
  • Hospital (monitoring equipment, nurses' stations)
  • Hospitality/Restaurant (credit card/debit card reader, serial printers)
  • Hotel Front Desk (serial printers, bar code scanners, keyboard, mouse, receipt printer, credit/debit card reader)
  • Manufacturing (CNC machinery, process control equipment, bar code scanners, serial printers)
  • POS (credit/debit card readers, receipt printers, bar code scanners, cash registers, scales)
  • Security (UPS control, access key panels, video cameras, card readers)

The StarTech.com Advantage

  • Add one network-enabled RS-232 Serial port to any Ethernet network
  • Allows several users share a serial device
  • No need to setup numerous and costly dedicated serial device servers, manage serial devices from a single PC
  • Operates seamlessly with built-in serial ports, the remote serial ports appear alongside other serial ports in your Windows device manager
  • Works over the Internet!

Partner Numbers

  • Ingram Micro Belgium 1861355
  • UPC 065030818865

Compatibility

  • Windows 8 logo
  • Windows 7 logo
  • Linux logo
Windows® 8 / 8.1 (32/64bit), 7 (32/64), XP (32), 2000 (32)
Windows Server® 2008 R2
Linux 2.4.x and up

Specifications

Warranty Information Warranty 2 Years
Connector(s) 1 - Connector Type(s) DB-9 (9 pin, D-Sub)
RJ-45
Environmental Operating Temperature 0° to 70° C
Hardware Ports 1
Interface Serial
Packaging Information Package Length 23,6 cm [9,3 in]
Package Width 11 cm [4,3 in]
Package Height 62 mm [2,4 in]
Shipping (Package) Weight 0,5 kg [1,1 lb]
Performance Max Baud Rate 115.2 Kbps
Supported Protocols RS-232, TCP/IP, UDP, HTTP, ICMP, TFTP
Physical Characteristics Color Beige
Product Length 13 cm [5,1 in]
Product Width 95 mm [3,7 in]
Product Height 4,4 cm [1,7 in]
Weight of Product 227 g [8,0 oz]
Power Power Source AC Adapter Included
Output Voltage 12V DC
Output Current 200 mA
Center Tip Polarity Positive
Software OS Compatibility Windows® 8 / 8.1 (32/64bit), 7 (32/64), XP (32), 2000 (32)
Windows Server® 2008 R2
Linux 2.4.x and up
Special Notes / Requirements Note All modes other than Driver Mode operate independently of the operating system
What's in the Box 1 - Included in Package Serial over IP Unit
Power Adapter
Instruction Manual

Accessories

AT925FM

DB9 to DB25 Serial Cable Adapter - F/M

Convert a DB9 male port to a DB25 male port

Your price
€3,99 EUR excl. VAT
€4,83 EUR incl. VAT
GC9SF

Slimline DB9 Serial Gender Changer - F/F

Convert a DB9 9-pin male connector into a DB9 9-pin female connector

Your price
€2,99 EUR excl. VAT
€3,62 EUR incl. VAT
Discontinued
Your price
€5,99 EUR excl. VAT
€7,25 EUR incl. VAT

Drivers/Downloads

Talk to an Advisor

We are always ready to assist you with any questions you may have.

Live Chat (opens in new window)

Driver(s):

Firmware

Manual(s):

Datasheet

Product Support

Talk to an Advisor

We are always ready to assist you with any questions you may have.

Live Chat (opens in new window)

Frequently Asked Questions

Troubleshooting

This device's default static IP address is 192.168.0.35.

When experiencing either issue, complete the following:

  1. Close the IP-Extender Manager software.
  2. Right-click on the IP-Extender Manager icon and click Properties.
  3. Click the Compatibility tab.
  4. Select the Run this program as an administrator check box.
  5. Click Apply and OK.
  6. Relaunch the software.

There are several different ways that you can reset these devices to the factory settings. The following steps list the methods in order of easiest to hardest to perform.

Use the included software

  1. Open IP-Extender Manager.
  2. Right-click the serial over IP device and click Advanced.
  3. Click Restore Defaults.

Use the web interface

  1. To log into the web interface for the unit, type its IP address into a web browser and enter the password. By default, the password is admin.
  2. Click Network Settings.
  3. Click Restore factory defaults and reboot device.

Note: You can reset individual ports by going into Port Configuration and clicking the Reset button underneath Port Reset.

Reset the hardware

  1. Disconnect all of the cables from the serial over IP device. There should not be anything plugged into it.
  2. Remove the four screws from the bottom of the unit.
  3. Remove the cover.
  4. Short J15 (located near the Ethernet connection) with a jumper.
  5. Reconnect the Ethernet cable.
  6. Reconnect the power cable.
  7. The orange light on the Ethernet connection will illuminate and the green light will stay dark.
  8. When the green light comes on, the hard reset procedure is complete.
  9. Disconnect both cables from the serial over IP device.
  10. Remove the jumper from J15.
  11. Replace the cover.
  12. Replace the four screws.
  1. Make sure that the serial device is on the same network as your computer.
  2. In an Internet browser, enter the IP address of the unit. The default IP address is 192.168.0.35.
  3. In the password field, enter the password. The default password is admin.
  4. Click Configure.

This is normal behavior. The software says connecting when data is being transferred. When data is not being transferred, the software says disconnected. The disconnected message does not mean that the device is not working.

If you are experiencing any issues in Windows 8 with the IP-Extender Manager software, complete the following:

  1. Right-click on the IP-Extender Manager software and click Properties.
  2. Click the Compatibility tab.
  3. Choose to Run this software in compatibility mode for Windows 7.
  4. Select the Run this program as an administrator check box.
  5. Click Apply and OK.

You should not upgrade your device's firmware if you do not have any issues with the functionality of your device. The only time you should consider an upgrade is if you are experiencing a problem with the device, and you have confirmed that the firmware addresses this problem.  You can confirm this is the case by reviewing the documentation included with the firmware or by consulting with our Technical Support team. Incorrectly upgrading firmware can result in diminished performance so it is best to contact StarTech.com if you would like to perform this operation.

Compliance and safety

Compliance letters

Safety Measures

  • If product has an exposed circuit board, do not touch the product under power.
  • If Class 1 Laser Product. Laser radiation is present when the system is open.
  • Wiring terminations should not be made with the product and/or electric lines under power.
  • Product installation and/or mounting should be completed by a certified professional as per the local safety and building code guidelines.
  • Cables (including power and charging cables) should be placed and routed to avoid creating electric, tripping or safety hazards.
*Product appearance and specifications are subject to change without notice.

Customer Reviews

(0 reviews)
0 out of 5 stars
  • 5 (0)
  • 4 (0)
  • 3 (0)
  • 2 (0)
  • 1 (0)
Tell us what you think of this product.
Need a little help getting started?

Check out our review guidelines.

Wait...
Back to top