StarTech.com

2x M.2 NGFF SSD RAID controller kaart met 2x SATA III poorten - PCIe

Voeg twee Next Generation Form Factor M.2 SSD's en twee SATA-poorten toe aan uw computer via PCI Express

Productcode: PEXM2SAT3422

  • Herstel data of verbeter de prestatie en opslagcapaciteit van uw desktop door twee M.2 solid-state drives (SSD) plus twee SATA III schijven toe te voegen
  • Creëer een hoogwaardige hardware RAID array voor het beschermen en back-uppen van uw data of uitbreiden van uw opslag — ondersteunt RAID 0, 1, 10 (1+0)
  • Brede installatiecompatibiliteit dankzij ondersteuning van vrijwel alle M.2 NGFF-schijven (22110, 2280, 2260, 2242, 2230) alsmede hybride schijven
Bekijk meer
  • Met poortmultiplier kunt u tot in totaal zeven schijven, inclusief twee M.2 schijven, aansluiten.
  • Twee M.2 B-Key geïntegreerde contacten die SATA III transmissiesnelheden tot 6 Gbps ondersteunen
  • Verstelbare stand-offs en meerdere montagegaten ondersteunen 110 mm, 80 mm, 60 mm, 42 mm en 30 mm SSD's
  • Snelle, probleemloze installatie met native ondersteuning van de meeste besturingssystemen
  • Voldoet aan de PCI Express 2.0-specificaties
  • Ondersteunt Native Command Queuing (NCQ) en ATA- en ATAPI-commando's
  • Gevoed via de PCIe-bus, of door de stroomvoorziening van de computer via een 4-pin floppy-voedingsconnector (small drive power)
  • Uitgerust met een full-profile steun, terwijl een low-profile (halfhoge) steun wordt meegeleverd voor installatie in kleine-vormfactorcomputers.
  • Voor installatie in x4, x8 of x16 PCIe sleuven
€ 115,99 EUR exc BTW
€ 140,35 EUR inc BTW

Overzicht

Met deze M.2 SSD RAID controllerkaart kunt u twee M.2 NGFF (Next Generation Form Factor) schijven in uw desktopcomputer installeren. De kaart heeft ook twee SATA III (6Gbps) poorten en ondersteunt hardware RAID. Nu kunt u de snelheid en compactheid van M.2 solid state drives (SSD) combineren met de opslagcapaciteit van traditionele harde schijvenven (HDD).

Benut de afmeting en snelheid van M.2 schijven

Met deze M.2 controllerkaart kunt u profiteren van de afmeting en prestaties van NGFF SSD's. M.2 schijven zijn kleiner dan typische platterschijven of op mSATA gebaseerde SSD's, zodat u deze in kleine vormfactor pc's en servers of op nauwere plaatsen in uw computerbehuizing kunt installeren.

Als u de kaart combineert met een M.2 schijf, kunt u de snelheid van uw computer aanzienlijk verhogen. Door installatie van uw besturingssysteem op de M.2 schijf hebt u sneller toegang tot de bestanden die u vaak gebruikt en kunt u uw platter-HDD met hogere capaciteit voor bulkopslag benutten.

Gemoedsrust door eenvoudig en voordelig dataherstel

Vanwege hun prestaties en gunstige afmetingen worden M.2 schijven vaak gebruikt in laptops. Als uw laptop defect is, maar de M.2 schijf nog werkt, dan kan deze kaart helpen bij het herstel van data. Als de M.2 schijf eenmaal is geïnstalleerd en de data zijn hersteld, kunt u de schijf voor opslag en back-up blijven gebruiken.

Bouw een krachtige RAID array

Als u een schaalbare, interne opslagoplossing nodig hebt waarop u kunt vertrouwen, kan deze kaart u helpen. De kaart ondersteunt diverse RAID configuraties (RAID 0, 1 en 10), waardoor u meerdere mogelijkheden hebt om uw opslag uit te breiden, de prestatie van uw computer te verbeteren en data-redundantie back-ups kunt maken.

Sluit zelfs nog meer schijven aan met poortmultiplicatie

Omdat de M.2 kaart poortmultiplicatie ondersteunt, kunt u tot vier schijven aansluiten op een van de SATA-poorten van de kaart. Dankzij de ingebouwde poortmultiplier kunt u tot zeven schijven (twee M.2 SSD's, vijf SATA-schijven) in uw computer installeren via deze enkelvoudige schijfcontroller.

Ondersteunt vele verschillende schijven

U kunt ervan verzekerd zijn dat uw M.2 SATA-schijven compatibel zijn met deze kaart. De controllerkaart ondersteunt de meest gebruikte schijfmaten, waaronder 22110, 2280, 2260, 2242 en 2230. Voor nog meer veelzijdigheid ondersteunt de kaart ook hybride schijven.

De PEXM2SAT3422 wordt gedekt door een 2-jarige garantie en gratis levenslange technische ondersteuning van StarTech.com.

Toepassingen

Verhoog de interne opslagcapaciteit van uw standaard of kleine vormfactor computer

Maak een RAID array en voeg de beveiliging van dataredundantie en meer opslagruimte toe aan uw pc

Krijg toegang tot en herstel data van vrijwel elke M.2 SSD, zoals schijven die van laptops en andere computers afkomstig zijn

Optimaliseer uw systeem voor I/O-intensieve applicaties zoals Office Suites, bewerken van foto's/video's en mediaspelers

Technische specificaties

Garantie
Garantie 2 Years
Hardware
Bus type PCI Express
Chipsetcode Marvell - 88SE9230
Industriestandaarden Seriële ATA 3.0 specificatie - SATA I/II/III (1,5/3/6 Gbps)
PCI Express 2.0
Hardware RAID 0, RAID 1 / RAID 10
Interface M.2 SATA
SATA
Kaarttype Standaard bracket (incl. low profile bracket)
Poorten 2
Poorttype Geïntegreerd op kaart
Prestaties
ATAPI Support Ja
Bootable Ja
Number of Drives Supported Through Port Multiplier 1 to 4
Number of Ports That Support Port Multiplier 2 (can only use 1 PM at a time)
Ondersteunde RAID-niveaus JBOD - (Just a Bunch of Disks)
RAID 1 (mirror)
RAID 0 (stripe)
RAID 10 (1+0, stripe + mirror)
Port-multiplier Ja
RAID Ja
Type en snelheid SATA III (6 Gbps)
Connector(en)
Interne poorten 2 - M.2 SATA (NGFF, B-Key) Contact
2 - SATA (7-polig, data) Stekker
1 - SP4 (4-polig, Small Drive Power) Mannelijk
Type connector(en) 1 - PCI Express x4 Mannelijk
Software
Besturingssystemen Windows® XP, Vista, 7, 8, 8.1, 10
Windows Server® 2003, 2008 R2, 2012, 2012 R2, 2016
Mac OS® 10.6 to 10.13
Linux 3.5.x to 4.11.x LTS versions only
Note: Connected drives cannot be used as System / Primary drive in Windows Server 2012, 2012 R2, 2016
Speciale opmerkingen / vereisten
Notitie De maximale throughput van deze kaart is beperkt door de businterface. In combinatie met voor PCI Express Gen 1.0 geschikte computers is de max. throughput 2,5 Gbps per baan. In combinatie met voor PCI Express Gen 2.0 geschikte computers is de max. throughput 5 Gbps per baan.
De twee SATA-poorten van de kaart ondersteunen poortmultiplier, tot in totaal zeven schijven (inclusief twee M.2 schijven). Slechts één SATA-poort kan tegelijkertijd poortmultiplier gebruiken, met tot in totaal vier schijven aangesloten via PM (in een niet-RAID configuratie)
Systeem- en kabelvereisten PCI Express x4 sleuf (neerwaarts compatibel met x8 en x16 sleuven)
Indicatoren
LED-indicatoren 2 - M.2 schijf-LED's (groen)
3 - Pin headers voor LED's
Gebruiksomgeving
Bedrijfstemperatuur 5°C to 50°C (41°F to 122°F)
Opslagtemperatuur -25°C to 70°C (-13°F to 158°F)
Vochtigheid 20%~80% RV (niet-condenserend)
Fysieke eigenschappen
Breedte product 20 mm [0.8 in]
Gewicht product 68 g [2.4 oz]
Hoogte product 120 mm [4.7 in]
Lengte product 180 mm [7.1 in]
Verpakkingsinformatie
Verzendgewicht (verpakt) 174 g [6.1 oz]
Wat wordt er meegeleverd
Meegeleverd 1 - M.2 SSD RAID controllerkaart
1 - Low-profile-bracket
2 - M.2 montageschroeven
1 - verkorte handleiding

Compatibiliteit

Bekijk volledige OS compatibiliteit
Windows® XP, Vista, 7, 8, 8.1, 10
Windows Server® 2003, 2008 R2, 2012, 2012 R2, 2016
Mac OS® 10.6 to 10.13
Linux 3.5.x to 4.11.x LTS versions only
Note: Connected drives cannot be used as System / Primary drive in Windows Server 2012, 2012 R2, 2016

Certificaties

Verwante producten

2x M.2 SSD controller kaart - PCI Express kaart
PEX2M2
2x M.2 SSD controller kaart - PCI Express kaart

Voeg twee Next Generation Form Factor (NGFF) M.2 SATA SSD's toe aan uw computer via PCI Express

€ 95,99 exc BTW
€ 116,15 inc BTW
M.2 SSD naar 2,5 inch SATA-adapter / converter
SAT32M225
M.2 SSD naar 2,5 inch SATA-adapter / converter

Verander een M.2 SSD in een 7 mm hoge 2,5 inch SATA 6 Gbps Open Frame SSD

€ 29,99 exc BTW
€ 36,29 inc BTW
4x M.2 SATA monteerbare adapter voor 3,5 inch drive bay
35S24M2NGFF
4x M.2 SATA monteerbare adapter voor 3,5 inch drive bay

Verbeter uw systeem door vier M.2 SATA SSD's in één 3,5 inch drive bay te monteren

€ 65,99 exc BTW
€ 79,85 inc BTW
M.2 naar SATA SSD-adapter – in uitbreidingssleuf gemonteerd
S32M2NGFFPEX
M.2 naar SATA SSD-adapter – in uitbreidingssleuf gemonteerd

Monteer een M.2 NGFF SSD in uw desktop computer met een standaard SATA-hostverbinding

€ 24,99 exc BTW
€ 30,24 inc BTW
M.2 naar SATA externe SSD-behuizing - USB 3.0 met UASP - externe behuizing
SM2NGFFMBU33
M.2 naar SATA externe SSD-behuizing - USB 3.0 met UASP - externe behuizing

Verander uw solid state drive in een zeer mobiele pocketschijf

€ 39,99 exc BTW
€ 48,39 inc BTW
M.2 SSD naar 2,5 inch SATA III-adapter - Solid-State Drive Converter met beschermende behuizing
SAT2M2NGFF25
M.2 SSD naar 2,5 inch SATA III-adapter - Solid-State Drive Converter met beschermende behuizing

Verander een M.2 solid state drive in een standaard 2,5 inch 6 Gbps vormfactor-SSD

€ 34,99 exc BTW
€ 42,34 inc BTW
2-poorts PCI Express 2.0 SATA III 6 Gbps RAID controllerkaart met 2 mSATA-sleuven en HyperDuo SSD Tiering
PEXMSATA3422
2-poorts PCI Express 2.0 SATA III 6 Gbps RAID controllerkaart met 2 mSATA-sleuven en HyperDuo SSD Tiering

Combineer SSD-prestaties met HDD-capaciteit om een HyperDuo array te maken met 2 mSATA- en 2 SATA-schijven via één PCI Express-sleuf

€ 115,99 exc BTW
€ 140,35 inc BTW
3-poorts PCI Express 2.0 SATA III 6 Gbps RAID controllerkaart met mSATA-sleuf en HyperDuo SSD Tiering
PEXMSATA343
3-poorts PCI Express 2.0 SATA III 6 Gbps RAID controllerkaart met mSATA-sleuf en HyperDuo SSD Tiering

Voeg 1 interne mSATA-sleuf en 3 interne SATA III (6 Gbps)-poorten toe aan een computer via een PCI Express x2-sleuf

€ 52,99 exc BTW
€ 64,12 inc BTW
4-poorts PCI Express 2.0 SATA III 6 Gbps RAID-controllerkaart met HyperDuo SSD Tiering
PEXSAT34RH
4-poorts PCI Express 2.0 SATA III 6 Gbps RAID-controllerkaart met HyperDuo SSD Tiering

Voeg 4 interne SATA III (6 Gbps)-poorten toe aan een computer met een PCI Express x2-sleuf

€ 107,99 exc BTW
€ 130,67 inc BTW

Accessoires

Productondersteuning

Drivers en downloads

Software
Specificatieblad(en)

Veelgestelde vragen (FAQ)

Voor uw aanschaf

Although M.2 SSDs come in similar form factors, only an M.2 SATA drive with an NGFF B key will operate with this device. M.2 drives that are PCIe or have a different key position are not compatible with this device.

This device can adapt an M.2 SATA drive to standard SATA connections, which is not possible for a PCIe based M.2 drive. The key type refers to the connector type on the M.2 SATA drive. B key can be M.2 PCIe x2 or SATA, so it is important that you check the specifications of the drive to see if it supports SATA.

This device supports the ATA Packet Interface (ATAPI) protocol. ATAPI is required for optical drives, including CD-ROM drives, DVD-ROM drives, and Blu-ray players. Because this device supports ATAPI, optical drives are also supported.

 

Note: Not all StarTech.com devices support each of the RAID modes described below. For more information on the RAID modes that your device supports, refer to the manual or the StarTech.com product page.

Redundant Array of Independent Disks (RAID) is a virtual disk technology that combines multiple physical drives into one unit. RAID can create redundancy, improve performance, or do both.

RAID should not be considered a replacement for backing up your data. If critical data is going onto a RAID array, it should be backed up to another physical drive or logical set of drives.

The following are terms that are normally used in connection with RAID:

  • Striping: data is split between multiple disks.
  • Mirroring: data is mirrored between multiple disks.
  • Parity: also referred to as a checksum. Parity is a calculated value used to mathematically rebuild data.

Different RAID levels exist for different application requirements.

Refer to the following table for the list of RAID modes offered by some StarTech.com products:

RAID mode Description Operation Advantages Disadvantages Recovery
RAID 0 Striped disks Data is split evenly between two or more disks. Large size and the fastest speed. No redundancy. If one or more drives fails, this results in array failure.
RAID 1 Mirrored disks Two or more drives have identical data on them. A single drive failure will not result in data loss. Speed and size is limited by the slowest and smallest disk. Only one drive is needed for recovery.
RAID 3 Striped set with dedicated parity Data is split evenly between two or more disks, plus a dedicated drive for parity storage. High speeds for sequential read/write operations. Poor performance for multiple simultaneous instructions. A single drive failure will rebuild.
RAID 5 Striped disks with distributed parity Data is split evenly between three or more disks. Parity is split between disks. Large size, fast speed, and redundancy. The total array size is reduced by parity. A single drive failure will rebuild.
RAID 10 1+0; Striped set of Mirrored Subset Four or more drives are made into two mirrors that are striped. Larger size and higher speed than RAID-1, and more redundancy than RAID-0. No parity. Only one drive in a mirrored set can fail.
JBOD Just a Bunch Of Disks Any number of drives are accessed independently by the operating system. Software RAID modes can be used. Hardware RAID may have better performance. N/A
Big Spanning or Concatenation Data is written on one drive until it is full, and then the next drive(s) until it or they are full. Creates a very large and simple array.

No redundancy.

N/A
Clone RAID 1 + Spare

Two drives have identical data, plus one drive is used for rebuilding in case of a primary array failure.

Seamless operation when one drive fails in a RAID-1 array. Spare drive is not accessible to the user. Only one drive is needed for recovery.

 

Installatie

Before you install the device, make sure that your operating system is current (for example, the most recent service pack is installed).

  1. Download the latest drivers from the StarTech.com website at http://www.startech.com/Support. The part number and product ID are on the product packaging.

Note: Windows usually saves the files to the Downloads folder that is associated with your user account (for example, C:\Users\your_name\Downloads).

  1. After the download is complete, right-click the zip folder that you downloaded, click Extract All, and complete the instructions.
  2. In the list of extracted files, right-click the Setup.exe file and click Run as Administrator.

Note: If the Run as Administrator option is not available, you might be attempting to run the installer from within the zipped file. Extract the files using the instructions in step 2.

  1. Complete the instructions to install the device drivers, and restart your computer when prompted to.

Your computer will automatically complete the driver installation and your device should be ready to use.

Hoe gaat u te werk

To confirm that Windows detects your expansion card, complete the following:

  1. Press the Windows key+R, type devmgmt.msc, and press Enter.
  2. In Device Manager, under the appropriate heading, confirm that your expansion card is listed and that there isn't an exclamation mark next to it.  For example, a USB controller card would be under Universal Serial Bus controllers.

Your expansion card is listed according to the name of the chipset. To determine the name of the chipset of your expansion card, navigate to www.StarTech.com and look on the Technical Specifications tab for your product.

To confirm that the Mac OS detects your expansion card, complete the following:

  1. Click the Apple icon.
  2. Click About This Mac.
  3. Click More Info or System Report.
  4. Under the appropriate heading, confirm that your expansion card is listed and that there isn't an error. For example, a network card would be under Ethernet Cards.

Your expansion card is listed according to the name of the chipset. To determine the name of the chipset of your expansion card, navigate to www.StarTech.com and look on the Technical Specifications tab for your product.

In order to use a hard drive plugged into a hard drive controller card as your operating system, you need to install the operating system onto the hard drive while it is plugged into the expansion card. To do this, complete the following:

Note: Not all hard drive controller cards have drivers that allow you to install the operating system onto the hard drive. All of the hard drive controllers that display this FAQ include this capability.

Before you begin, consult the documentation that came with the motherboard to make sure that the motherboard or BIOS supports booting from an expansion card.

  1. Back up any data on the hard drive.
  2. Make a copy of the drivers from the website onto a floppy disc, CD, DVD, or USB flash drive. The drivers that you download depends on the operating system that you want to install.
  3. Install the hard drive controller card onto your motherboard.
  4. Plug the hard drive into the controller card.
  5. Turn on your computer and open the operating system install wizard.
  6. Before you select the hard drive that you want to install the operating system onto, select the option to install third-party drivers.
  7. Point the driver installer to the floppy disc, CD, DVD, or USB flash drive.
  8. Install the drivers.
  9. Select the hard drive on the hard drive controller card as the location where you want to install the operating system.
  10. Complete the on-screen instructions to finish installing the operating system.

Troubleshooting

When you troubleshoot issues with a hard drive controller card, there are some quick tests that you can complete to rule out potential problems. You can test to make sure that the following components are working correctly and are not the source of the issue:

  • IDE, SATA, and eSATA cables

  • Hard drives

  • Hard drive controller card

To test your setup components, try the following:

  • Use the IDE, SATA, or eSATA cable, hard drive, and hard drive controller card in another setup to see if the problem is with the components or the setup.

  • Use a different IDE, SATA, or eSATA cable, hard drive, and hard drive controller card in your setup to see if the problem persists. Ideally, you should test a component that you know works in another setup.

When you test your cables, it is recommended that you do the following:

  • Test each cable individually.

  • Use short cables when you are testing.

When you test the hard drive and hard drive controller card, it is recommended that you do the following:

  1. To open the Device Manager, press the Windows key + R, type devmgmt.msc, and press Enter. Check the IDE ATA/ATAPI controllers (for IDE) section, or the Storage controllers (for SATA) section.

  2. Do one of the following:

Note: Formatting a hard drive erases all of the data on it. Make sure that you back up all of your data before you reformat the hard drive.

  1. To check Disk Management, press the Windows key + R, type diskmgmt.msc, and press Enter. Check to see if your hard drive is listed.

  2. If the hard drive is listed as healthy but does not have a drive letter, for example, C:, right-click healthy and click Change Drive Letter and Paths. Click Add, assign a drive letter, and click OK.

Note: A formatted hard drive does not show up in Computer or My Computer until it has a drive letter assigned to it.

In order to rebuild a RAID array, you need to replace a physical drive with an identical drive on the same RAID controller. Although standard RAID levels are generally agreed upon throughout the industry, the implementation varies between manufacturers. RAID arrays are typically not accessible when they are moved to another controller, and data may be unrecoverable if the drives are out of order or have been formatted or accessed by another RAID controller.

If a RAID controller has failed, you should get the exact same model of RAID controller.  

Note: If a drive or drives were damaged, it is possible that the RAID array may be permanently unrecoverable.

RAID should not be considered a replacement for backing up your data. If critical data is going onto a RAID array, you should back up the data on another physical drive or logical set of drives.

Rebuild a RAID array

With the following RAID modes, recovery is possible using the same StarTech.com product. Refer to the following table for the appropriate method to use to recover your RAID array.

RAID mode Max # of failed drives Procedure
RAID 1 Only one drive is needed for recovery.
  1. Determine which drive is operational by using the RAID management utility (if available) or test each drive individually on a different hard drive controller (for example, a hard drive docking station or SATA controller).

  2. Replace the failed drive with an identical hard drive.

The array will rebuild and is accessible during the rebuilding process.

RAID 3 Single drive failure will rebuild.
  1. Determine which drive is defective by using the RAID management utility (if available) or with diagnosis LEDs on the controller or enclosure.

  2. Replace with an identical hard drive.

Note: Do not change the order of the drives.

  1. The array may be accessible during the rebuild, but you should let the controller rebuild without interruption so that performance is not compromised.

RAID 5 Single drive failure will rebuild.
  1. Determine which drive is defective by using the RAID management utility (if available) or with diagnosis LEDs on the controller or enclosure.

  2. Replace with an identical hard drive.

Note: Do not change the order of the drives.

  1. The array may be accessible during the rebuild, but you should let the controller rebuild without interruption so that performance is not compromised.

RAID 10 Only one drive in a mirrored set can fail.
  1. Determine which drive is defective by using the RAID management utility (if available) or with diagnosis LEDs on the controller or enclosure.

  2. Replace with an identical hard drive.

Note: Do not change the order of the drives.

  1. The array may be accessible during the rebuild, but you should let the controller rebuild without interruption so that performance is not compromised.