Niet meer leverbaar

2 Port CardBus RS232 Serial Laptop PC Adapter Card - 16950

Productcode: CB2S950

  • High Performance 16C950 UART with maximum data transfer rate up to 921.6 Kbps
  • 128-byte deep FIFO data buffer
  • Offers 2 DB9 RS-232 ports to connect multiple devices to a notebook PC

This CardBus RS232 Serial Laptop PC Adapter Card adds two RS232 serial ports to a notebook computer, letting you connect your mobile computer to serial peripheral devices.

Supporting data transfer rates of up to 921.6 Kbps, the RS232 serial adapter features a high performance 16950 UART chipset, ensuring flawless connectivity with your serial peripherals.

The adapter is backed by StarTech.com's Lifetime Warranty and free, lifetime technical support.

Toepassingen

  • Works with serial modems, POS devices, PDAs, digital cameras, printers, ISDN terminal adapters, and more.
  • Connect up to 2 RS-232 serial devices to a CardBus slot on your notebook.

Het voordeel van StarTech.com

  • Connect serial devices to any notebook with an available CardBus slot.
  • Free Lifetime Technical Support
  • StarTech.com's Lifetime Warranty
  • Supports the RS232 specification

Partnernummers

  • UPC 065030824347

Compatibility

  • Windows 7 logo
  • Linux logo
  • Windows Server 2012 logo
  • Windows 8 logo
Windows® 8 / 8.1 (32/bit), 7 (32/64), Vista (32/64), XP (32/64), 2000, ME, 98SE, 95
Windows Server® 2012, 2008 R2, 2003 (32/64)
Linux 3.5

Specificaties

Warranty Information Warranty Lifetime
Connector(en) 1 - Type connector(en) PC Card (type II, Cardbus)
2 - Externe poorten DB-9 (9-polig, D-Sub)
Fysieke eigenschappen Lengte product 12 cm [4,7 in]
Breedte product 60 mm [2,4 in]
Hoogte product 24 mm [0,9 in]
Gewicht product 250 g [8,8 oz]
Gebruiksomgeving Bedrijfstemperatuur -10°C to 80°C (14°F to 176°F)
Opslagtemperatuur -20°C to 100°C (-4°F to 212°F)
Vochtigheid 5~85% RH
Hardware Poorten 2
Interface Serieel
Bus type CardBus (PCMCIA)
Poorttype Dongle (meegeleverd)
Chipsetcode PLX/Oxford - OX16PCI952
Prestaties Seriële protocol RS-232
Max. baudrate 921,6 kbit/s
FIFO 128 Bytes
Software Besturingssystemen Windows® 8 / 8.1 (32/bit), 7 (32/64), Vista (32/64), XP (32/64), 2000, ME, 98SE, 95
Windows Server® 2012, 2008 R2, 2003 (32/64)
Linux 3.5
Verpakkingsinformatie Package Length 20,7 cm [8,1 in]
Package Width 14 cm [5,5 in]
Package Height 38 mm [1,5 in]
Verzendgewicht (verpakt) 280 g [9,9 oz]
Wat wordt er meegeleverd 1 - Meegeleverd CardBus Serial Card
2 Port DB9 Breakout Cable
Driver CD
Instruction Manual

Accessoires

AT925FF

DB9-naar-DB25 seriële kabeladapter - F/F

Verandert een DB9 mannelijke poort in een DB25 vrouwelijke poort

Uw prijs
€3,99 EUR excl. VAT
€4,83 EUR incl. VAT
AT925FM

DB9 naar DB25 seriële adapterkabel - F/M

Verander een DB9 mannelijke poort in een DB25 mannelijke poort

Uw prijs
€3,99 EUR excl. VAT
€4,83 EUR incl. VAT

Drivers/Downloads

Praat met een adviseur.

Wij staan altijd klaar om al uw vragen te beantwoorden.

Chat Live (opens in new window)

Handleiding:

Datasheet

Productondersteuning

Praat met een adviseur.

Wij staan altijd klaar om al uw vragen te beantwoorden.

Chat Live (opens in new window)

Veelgestelde vragen (FAQ)

Installatie

Before you install the device, make sure that your operating system is current (for example, the most recent service pack is installed).

  1. Download the latest drivers from the StarTech.com website at http://www.startech.com/Support. The part number and product ID are on the product packaging.

Note: Windows usually saves the files to the Downloads folder that is associated with your user account (for example, C:\Users\your_name\Downloads).

  1. After the download is complete, right-click the zip folder that you downloaded, click Extract All, and complete the instructions.
  2. Press the Windows key + R, type devmgmt.msc, and press Enter to open the Device Manager.
  3. Right-click PCI Serial Port, which will have a “!” or “?” next to it to indicate a driver issue.
  4. Click Update Driver.
  5. Click Browse my computer for driver software.
  6. Select the Let me pick from a list of device drivers on my computer option.
  7. On the Select your device’s type from the list below screen, click Show All Devices, and click Next.

Note: The Select your device’s type from the list below screen does not appear on all systems. If you do not see this screen, skip this step.

  1. Select the Have Disk option.
  2. Browse to the Windows folder, select the folder for your operating system, and open the 32-bit or the 64-bit folder, depending on your system type.

Note: To view your system type, click Start. Right-click Computer, and then click Properties.

  1. Click the OxMf or OxPCIeMf file. Click OK, and then click Next.

Note: If you are using a serial card that uses the OxPCIeMf file and installation fails, repeat steps 4 to 9, then browse to the Windows folder. Browse to the Serial Port Driver folder and click the oxserleg file.  Click OK, and then click Next.

Troubleshooting

When you troubleshoot issues with a serial device, there are some quick tests that you can complete to rule out potential problems. You can test to make sure that the following components are working correctly and are not the source of the issue:

  • Serial cables

  • Serial ports

  • Serial devices

To test your setup components, try the following:

  • Use the serial cable, serial port, and serial device in another setup to see if the problem is with the components or the setup.

  • Use a different serial cable, serial port, and serial device in your setup to see if the problem persists. Ideally, you should test a component that you know works in another setup.

When you test your cables, it is recommended that you do the following:

  • Test each cable individually.

  • Use short cables when you are testing.

When you test the serial ports and serial device, it is recommended that you do the following:

Note: Some serial devices work only if the COM port number is between a certain range. For example, COM1 to COM4.

To check whether or not an RS-232 serial port is working, perform an RS-232 loopback test by doing the following:

  1. If your serial port is not female, convert it by taking a female/female cable or gender changer and plugging it into the serial port.
  2. Take a metal paperclip or wire and cross pins 2 and 3. If you look closely at the female end, the pins should be numbered.
  3. Open a telnet session on the COM port number of the device that you are testing. To find out the COM port number, refer to the following FAQ: https://www.startech.com/faq/com-port-listing-windows.

Note: To open a telnet session on the COM port, you need a telnet client like PuTTY or Hyper Terminal. Windows XP comes with Hyper Terminal.

  1. When the session is open, anything you type into it you should see. The loopback test fails when you cannot see what you are typing.

If the loopback test fails, make sure that the serial cable or gender changer that you are using works and that the adapter is in the correct port. 

You can check multiple ports at the same time by opening multiple sessions, putting the loopback adapter on one port, and trying to type into each session.  When you can see what you are typing, you know that the COM port is working and you can see which port number the physical serial port is. Close the window for the port that you just tested to speed up the testing of the remaining serial ports.

Compliance and safety

Compliance letters

Safety Measures

  • If product has an exposed circuit board, do not touch the product under power.
  • If Class 1 Laser Product. Laser radiation is present when the system is open.
  • Wiring terminations should not be made with the product and/or electric lines under power.
  • Product installation and/or mounting should be completed by a certified professional as per the local safety and building code guidelines.
  • Cables (including power and charging cables) should be placed and routed to avoid creating electric, tripping or safety hazards.
* Uitvoering en specificaties van het product zijn zonder aankondiging vatbaar voor wijzigingen.
Terug naar boven
Wacht...