Are you in the United States?
Visit our U.S.A. & International site for relevant pricing, distribution and product availability information.
Go to StarTech.comMPO/MTP to LC Breakout Cable - Plenum-Rated - OM3, 40Gb - Push/Pull-Tab - 10 m (30 ft.)
Fan out eight fibers from a 40Gbps MPO connection to four 10Gbps LC connections
Product ID: MPO8LCPL10M
- Obtain higher port density with eight LC network connections combined into a single MPO/MTP connector
- Optimize accessibility and install or remove connectors with one hand using the push-and-pull tabs
- Save space and improve cable management with slim uniboot connectors
- Get test data for your fiber cable - an insertion loss and return loss test report is included in each cable bag
Volume Order?
Request a quote
Reseller Pricing:
Create an Account
Overview
This MPO/MTP to 8x LC breakout cable lets you fan out a single 40Gbps connection from a 40GBase-SR4 QSFP+ transceiver to four 10Gbps LC SFP+ transceivers.
The push-and-pull tabs optimize accessibility and let you install or remove the connectors with one hand without using additional tools. Plus, the slim uniboot design of the LC connectors saves space and improves cable management.
The MPO cable is housed in a plenum-rated jacket and is ideal for in-wall installations or anywhere CMP fire rating is required.
Each OM3 fiber cable has been individually tested for insertion loss and return loss. The full test report is included in each cable bag.
The MPO8LCPL10M from StarTech.com is backed by a lifetime warranty.
Applications
Use in 10/40 Gigabit Ethernet and fiber channel applications
Fan out a single 40Gbps MPO/MTP connection to four 10Gbps LC connections on devices such as fiber patch panels, hubs, switch, media converters, and routers
Used with 40GBase-SR4 networking hardware
Technical Specifications
Product Numbers | ||
---|---|---|
Ingram Micro Canada | 8120YD | |
Tech Data Canada | 0S4167 | |
SYNNEX Canada | 6169323 | |
ASI Distribution Canada | 218372 | |
D&H Canada | MPO8LCPL10MCA | |
UPC Code | 065030879002 |
Warranty Information | ||
---|---|---|
Warranty | Lifetime | |
Hardware | ||
Fiber Size | 50/125 | |
Fire Rating | CMP Rated (Plenum) | |
Performance | ||
Fiber Classification | OM3 | |
Type | Multi Mode | |
Connector(s) | ||
Connector A | 1 - MPO/MTP Female | |
Connector B | 8 - Fiber Optic LC Duplex Male | |
Environmental | ||
Humidity | 55 ~ 65%RH | |
Operating Temperature | -10°C to 70°C (14°F to 158°F) | |
Storage Temperature | -10°C to 70°C (14°F to 158°F) | |
Physical Characteristics | ||
Cable Length | 32.8 ft [10 m] | |
Color | Aqua | |
Product Height | 0.3 in [8 mm] | |
Product Length | 32.8 ft [10 m] | |
Product Weight | 3.7 oz [104 g] | |
Product Width | 0.3 in [8.7 mm] | |
Packaging Information | ||
Shipping (Package) Weight | 4 oz [114 g] | |
What's in the Box | ||
Included in Package | 1 - fiber optic cable |
Related Products
MPO/MTP to LC Breakout Cable - Plenum-Rated - OM3, 40Gb - Push/Pull-Tab - 1 m (3 ft.)
Fan out eight fibers from a 40Gbps MPO connection to four 10Gbps LC connections
66+ In stock
In stock
CA: 4 | US: 62
In stock
Learn More
MPO/MTP to LC Breakout Cable - Plenum-Rated - OM3, 40Gb - Push/Pull-Tab - 2 m (6 ft.)
Fan out eight fibers from a 40Gbps MPO connection to four 10Gbps LC connections
132+ In stock
In stock
CA: 11 | US: 121
In stock
Learn More
MPO/MTP to LC Breakout Cable - Plenum-Rated - OM3, 40Gb - Push/Pull-Tab - 3 m (10 ft.)
Fan out eight fibers from a 40Gbps MPO connection to four 10Gbps LC connections
47+ In stock
In stock
CA: 8 | US: 39
In stock
Learn More
MPO/MTP to LC Breakout Cable - Plenum-Rated - OM3, 40Gb - Push/Pull-Tab - 5 m (15 ft.)
Fan out eight fibers from a 40Gbps MPO connection to four 10Gbps LC connections
96+ In stock
In stock
CA: 4 | US: 92
In stock
Learn More
Product Support
Diagram(s):
-
MPO8LCPLXXM_Drawing.pdf
- Language: English
Data Sheets
-
MPO8LCPL10M_Datasheet.pdf
- Language: English
Compliance and Safety
Compliance Letters
-
Country of Origin (COO)
- Language: English
-
Letter of Conformity (LOC)
- Language: English
-
Waste Electrical and Electronic Equipment Directive (WEEE)
- Language: English
Safety Measures
- If product has an exposed circuit board, do not touch the product under power.
- If Class 1 Laser Product. Laser radiation is present when the system is open.
- Wiring terminations should not be made with the product and/or electric lines under power.
- Product installation and/or mounting should be completed by a certified professional as per the local safety and building code guidelines.
- Cables (including power and charging cables) should be placed and routed to avoid creating electric, tripping or safety hazards.
* Product appearance and specifications are subject to change without notice.
Customer Reviews
(0 reviews)0 out of 5 stars
Quality of Product
Tell us what you think of this product.
Need a little help getting started? Check out our review guidelines.

MPO/MTP to LC Breakout Cable - Plenum-Rated - OM3, 40Gb - Push/Pull-Tab - 10 m (30 ft.)
Product ID: MPO8LCPL10M
Follow us on Twitter | Find us on Google+