Discontinued

4 Port Industrial RS-232 / 422 / 485 Serial to IP Ethernet Device Server - PoE-Powered - 2x 10/100Mbps Ports

Remotely manage 4 industrial RS232 or RS422/485 serial device over an IP network, with redundant 10/100 Ethernet ports

Product ID: NETRS42348PD

3 stars (1 reviews) |
  • Redundant power input via Power over Ethernet, or 12-48V DC terminal block
  • Redundant dual Ethernet ports with < 10ms recovery time
  • Up to 460.8 Kbps baud rate

The PoE-powered NETRS42348PD 4-Port Industrial Serial Device Server lets you remotely manage up to four industrial RS232/422/485 serial devices over a local or wide area network (LAN/WAN), with redundant power inputs and dual 10/100Mbps Ethernet ports.

To minimize downtime, this intuitive dual Ethernet serial over IP solution maintains connection to your critical equipment by automatically switching to its secondary LAN port within 10 milliseconds of a network failure or disruption.

Ideal for industrial environments, the serial to Ethernet device server accepts wide-range 12-48V DC power input via a terminal block, or through a PoE RJ45 port. Redundant power inputs keep the device server functional in the event of power surges or failures, and when used with a PoE-capable switch or injector, the serial device server can be conveniently installed in locations where terminal block power is unavailable.

This device server supports baud rates up to 460.8Kbps which provides a smooth, high-speed connection to your serial devices. The device server also offers support for HTTPS, SSH and SSL to ensure secure communication, while integrating support for IP, HTTP, ICMP, DHCP, TCP and UDP protocols. You can customize the serial device server to suit your application with versatile browser-based or virtual com port software configuration.

Ensuring performance in harsh environments, this serial device server offers 8KV air, and 4KV contact ESD (Electrostatic Discharge) protection and features a rugged, IP-30 case design that is both DIN rail and wall-mountable.

Backed by a 5-year StarTech.com warranty and free lifetime technical support.

Applications

  • Factory or warehouse environments subject to harsh conditions and large temperature variances
  • Industrial locations where critical equipment requires backup power and LAN connections
  • Manufacturing (CNC machinery, process control equipment, serial printers)
  • Security (UPS control, access key panels, video cameras, card readers)
  • Environmental Control (lighting, temperature, clocks)
  • POS (credit/debit card readers, receipt printers, cash registers, scales)

The StarTech.com Advantage

  • Maintain serial connectivity during disruptions with redundant power and network inputs
  • Suitable for harsh environments with ESD protection and a rugged, metal enclosure
  • Mount on DIN rails or on a surface with the attached mounting brackets

Partner Numbers

  • Tech Data 11331184
  • D&H NETRS42348PD
  • SYNNEX US STA-NETRS42348PD
  • UPC 065030854542

Compatibility

  • Windows 8 logo
  • Windows Server 2012 logo
  • Windows 10 logo
  • Windows Server 2016 logo
  • Windows Server 2019 logo
Windows® XP, Vista, 7, 8, 8.1, 10
Windows Server® 2003, 2008 R2, 2012, 2016, 2019

Specifications

Warranty Information Warranty 5 Years
Connector(s) Connector Type(s) 4 - DB-9 (9 pin, D-Sub)
2 - RJ-45
1 - Terminal Block (6 Wire)
Environmental Operating Temperature -10°C to 70°C (14°F to 158°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Humidity 5~95% RH (Non-Condensing)
Hardware Ports 4
Interface Serial
Industry Standards IEEE 802.3, IEEE 802.3u
IEEE 802.3af PoE
Indicators LED Indicators 1 - PoE
2 - Power
1 - Fault
4 - Serial
2 - Ethernet Link
Packaging Information Package Height 3.6 in [92 mm]
Package Length 9.3 in [23.7 cm]
Package Width 7.3 in [18.6 cm]
Shipping (Package) Weight 1.8 lb [0.8 kg]
Performance Maximum Data Transfer Rate 460.8 Kbps
Serial Protocol RS-232/422/485
Max Baud Rate 460.8 Kbps
Data Bits 5, 6, 7, 8
Flow Control XON/XOFF, RTS/CTS, DTR/DSR
Parity Odd, Even, None, Mark, Space
Stop Bits 1, 1.5, 2
Remote Management Ability Yes
Compatible Networks 10/100 Mbps
Auto MDIX Yes
Security Features 128-bit SSL Encryption
MTBF 569,972 Hours
Supported Protocols ICMP, IP, TCP, UDP, DHCP, BOOTP, SSH, DNS, SNMP V1/V2c, HTTPS, SMTP, SSL, PPPoE, DDNS
Physical Characteristics Color Black
Material Steel
Product Length 8.8 in [22.4 cm]
Product Width 8.3 in [210 mm]
Product Height 5.7 in [14.4 cm]
Weight of Product 25.8 oz [730 g]
Power Power Source Terminal Block
Input Voltage 12 ~ 48 DC
Software OS Compatibility Windows® XP, Vista, 7, 8, 8.1, 10
Windows Server® 2003, 2008 R2, 2012, 2016, 2019
Special Notes / Requirements Patents and Licenses The following patents are licensed for this product. This list might not be all inclusive.
• United States Patent No. 5,406,260 (expired)
• United States Patent No. 6,650,622
• United States Patent No. 7,457,250
• United States Patent No. 8,155,012
• United States Patent No. 8,902,760
• United States Patent No. 8,942,107
• United States Patent No. 9,019,838
• United States Patent No. 9,049,019
• United States Patent Application No. 14/695,456
• United States Patent Application No. 14/726,940
What's in the Box Included in Package 1 - Serial Device Server
1 - DIN-Rail Kit
1 - Wall-Mount Kit w/ Screws
2 - RJ-45 Dust Covers
1 - Installation Guide
1 - Software CD

Accessories

IES8100POE

8 Port 10/100 PSE Industrial Power over Ethernet Switch - All 8 Ports PoE

Connect Power and Data to 8 PoE-enabled Devices, with 15.4W per Port Output

Your price
$209.99USD

In stock: US: 64 | CA: 4

Where to buy StarTech.com products
POEINJ2GI

Industrial 2 Port Gigabit PoE+ Power over Ethernet Injector 48V / 30W - Wall-Mountable

Supply power and data connectivity to two Gigabit PoE devices over standard Ethernet cabling

Your price
$155.99USD

Check reseller availability

Where to buy StarTech.com products
AT925FM

DB9 to DB25 Serial Cable Adapter - F/M

Convert a DB9 male port to a DB25 male port

Your price
$7.99USD

In stock: US: 426 | CA: 41

Where to buy StarTech.com products
SCNM9FM

10 ft DB9 RS232 Serial Null Modem Cable F/M

Transfer files via serial connection

Your price
$7.99USD

In stock: US: 535 | CA: 96

Where to buy StarTech.com products
M45PATCH50BL

Cat5e Patch Cable with Molded RJ45 Connectors - 50 ft. - Blue

Make Fast Ethernet network connections using this high quality Cat5e Cable, with Power-over-Ethernet capability

Your price
$15.99USD

Check reseller availability

Where to buy StarTech.com products
45PATCH10BK

Cat5e Patch Cable with Snagless RJ45 Connectors - 10 ft, Black

Make Fast Ethernet network connections using this high quality Cat5e Cable, with Power-over-Ethernet capability

Your price
$8.99USD

In stock: US: 250 | CA: 870

Where to buy StarTech.com products
SCNM9FF

10 ft DB9 RS232 Serial Null Modem Cable F/F

Transfer files via serial connection

Your price
$7.99USD

In stock: US: 6653 | CA: 365

Where to buy StarTech.com products
GC9SF

Slimline DB9 Serial Gender Changer - F/F

Convert a DB9 9-pin male connector into a DB9 9-pin female connector

Your price
$6.99USD

In stock: US: 2309 | CA: 128

Where to buy StarTech.com products

Drivers/Downloads

Talk to an Advisor

We are always ready to assist you with any questions you may have.

Live Chat (opens in new window)

Firmware

Manual(s):

Software

Datasheet

Product Support

Talk to an Advisor

We are always ready to assist you with any questions you may have.

Live Chat (opens in new window)

Frequently Asked Questions

Troubleshooting

To check whether or not an RS-232 serial port is working, perform an RS-232 loopback test by doing the following:

  1. If your serial port is not female, convert it by taking a female/female cable or gender changer and plugging it into the serial port.
  2. Take a metal paperclip or wire and cross pins 2 and 3. If you look closely at the female end, the pins should be numbered.
  3. Open a telnet session on the COM port number of the device that you are testing. To find out the COM port number, refer to the following FAQ: https://www.startech.com/faq/com-port-listing-windows.

Note: To open a telnet session on the COM port, you need a telnet client like PuTTY or Hyper Terminal. Windows XP comes with Hyper Terminal.

  1. When the session is open, anything you type into it you should see. The loopback test fails when you cannot see what you are typing.

If the loopback test fails, make sure that the serial cable or gender changer that you are using works and that the adapter is in the correct port. 

You can check multiple ports at the same time by opening multiple sessions, putting the loopback adapter on one port, and trying to type into each session.  When you can see what you are typing, you know that the COM port is working and you can see which port number the physical serial port is. Close the window for the port that you just tested to speed up the testing of the remaining serial ports.

For products related to this article, click here.

You should not upgrade your device's firmware if you do not have any issues with the functionality of your device. The only time you should consider an upgrade is if you are experiencing a problem with the device, and you have confirmed that the firmware addresses this problem.  You can confirm this is the case by reviewing the documentation included with the firmware or by consulting with our Technical Support team. Incorrectly upgrading firmware can result in diminished performance so it is best to contact StarTech.com if you would like to perform this operation.

In order for the serial device and your computer to communicate to each other, they both need to be on the same physical network and the same subnet.

To connect your serial device and your computer to the same physical network, plug both devices into the same router. 

Typically, in order for devices to be on the same subnet, the first three numbers of the IP address must match. The fourth number of the IP address must be different, as two devices cannot have the same IP address. For example, if your computer’s IP address is 192.168.0.1, then the subnet is 192.168.0.XXX. You can replace the XXX with any number, as long as it is not currently in use by another device.

This device's default static IP address is 192.168.10.2.

Press the Reset button on the device for 5 seconds. The LEDs should blink to indicate that the device has been reset. 

How To

To troubleshoot this issue, you can try the following:

  • Ping the serial device.
  • Connect the serial device directly to the computer and ping the device.
  • Connect to the web interface (if there is one) or connect using the included software.

Before you begin, make sure that the serial device is on the same network and subnet. For more information, see this FAQ: http://www.startech.com/faq/serial_ip_networks_and_subnets.  If the device starts with an IP address that is not on your subnet, change your IP address to match the subnet being used before you continue.

Ping the serial device

If the serial device and your computer are on the same network and subnet, try pinging the device. 

To ping the device using a computer that is running a version of Windows XP, do the following:

  1. Click Start.
  2. Click Run.
  3. Type ping <IP address> and press Enter. For example, ping 192.168.0.20.

To ping the device using a computer that is running a version of Windows Vista or Windows 7, do the following:

  1. Click Start.
  2. Click Accessories.
  3. Click Command Prompt.
  4. Type ping <IP address> and press Enter. For example, ping 192.168.0.20.

To ping the device using a computer that is running a version of Windows 8, do the following:

  1. Press the Windows key + X.
  2. Click Run.
  3. Type cmd and press Enter.
  4. Type ping <IP address> and press Enter. For example, ping 192.168.0.20.

To ping the device using a computer that is running a version of Mac OS, do the following:

  1. Double-click the hard drive.
  2. Double-click Applications > Utilities > Network Utility.
  3. Click the Ping tab.
  4. Enter the IP address in the Please enter the network address to ping field.
  5. Enter the number of packets that you want to test with.

If you receive replies from the IP address, then you can see the device on the network and the issue is with something else.

Connect the serial device directly to the computer

To connect the serial device directly to the computer that you are troubleshooting with, complete the following:

  1. Use a crossover Ethernet cable to connect the device and the computer.
  2. Try pinging the device again.
  3. If you cannot ping the device, use a different computer, Ethernet cable, and serial device (if one is available).

Note: The second computer will need to be on the same network and subnet as the serial over IP device.

  1. If you still cannot ping the device, contact support.

Make sure that you are working in a secure environment

  1. Unplug the connection between your modem and your router. 
  2. Disable any firewalls (especially Windows Firewall), antivirus programs, and security programs that are currently running. 
  3. Try accessing the web interface (if the device has one) or try to connect using the included software.

If you still cannot connect to the device's web interface or by using the included software, contact support.

If you can access the web interface or connect using the included software, one at a time turn on your firewalls, antivirus programs, and security programs. Each time that you turn on software and cannot connect to the web interface or by using the included software, add an exception for the serial device to what you last re-enabled.

Before You Buy

Virtual COM port

One of the most common applications of a network serial device is to use it to make a standard serial device accessible on a network. To do this, you need to connect a standard serial device to the DB-9 port on the network serial device. Next you need to connect the network serial device to a TCP/IP network using an Ethernet connection, and then install software on a client machine in order to access the network serial device. The software on the client machine communicates with the network serial device and creates (maps) a virtual COM port on your computer system. The virtual COM port is identical to a physical COM port and can be used in the same way.

Serial IP extender

You can use two network serial devices to extend a serial connection over a TCP/IP network. To do this, you need to configure one serial device as a client and the other as a server. The client and server are configured to transmit and receive data to their respective IP addresses and TCP ports. The serial settings must match for all connected serial devices, including the UART on both units. Depending on the serial device that you are using, you can use the provided software or the web interface to set the configurations.

UDP to serial adapter

You can use a network serial device to translate UDP data to a standard serial connection. The serial device is configured to listen for UDP traffic from specific IP addresses and ports, and will asynchronously transmit the data out of the serial port on the device. To do this, you need to configure UART on the network serial device to match the specifications of the serial receiver.

Compliance and safety

Compliance letters

Safety Measures

  • If product has an exposed circuit board, do not touch the product under power.
  • If Class 1 Laser Product. Laser radiation is present when the system is open.
  • Wiring terminations should not be made with the product and/or electric lines under power.
  • Product installation and/or mounting should be completed by a certified professional as per the local safety and building code guidelines.
  • Cables (including power and charging cables) should be placed and routed to avoid creating electric, tripping or safety hazards.
*Product appearance and specifications are subject to change without notice.

Customer Reviews

(1 reviews)
3 out of 5 stars
  • 5 (0)
  • 4 (0)
  • 3 (1)
  • 2 (0)
  • 1 (0)
Tell us what you think of this product.
Need a little help getting started?

Check out our review guidelines.

1 - 1 of 1 Reviews
Sort
(3 Stars)

Driver issues

By: TJL1000 - 09/29/2017
Good if it worked out of the box, driver shipped with device is not digitally signed so have to download older driver from website. Issues with having to remap COM ports after disconnection to a serialdevice and reconnection with same COM port. Trying hard to be a MOXA but just not making it.
| Helpful?
Feedback Back to top