Product ID: PCI2S1P
In stock: CA: 48 | US: 881
The PCI2S1P PCI Serial/Parallel Combo Card turns a PCI slot into two external 16C550 serial ports and one external EPP/ECP parallel port - an all-in-one solution that gives you both parallel and serial connections while taking up only one PCI slot.
Suitable for installation in a small form factor computer, the PCI serial/parallel card includes an optional low profile/half-height mounting bracket that makes installation easy.
The serial/parallel combo card is PCI plug and play ready and supports IRQ sharing for fast, simple installation. The combo card is supported in virtually any Microsoft Windows operating environment (Windows® 7, Server 2008 R2, Vista, XP, ME, 2000, 98, 95 and NT4), and is backed by a StarTech.com Lifetime Warranty and free lifetime technical support.
Warranty Information | Warranty | Lifetime |
---|---|---|
Connector(s) | 1 - Connector Type(s) | PCI / PCI-X (Universal 3.3 & 5V, 32-bit) |
1 - External Ports | DB-25 (25 pin, D-Sub) | |
2 - External Ports | DB-9 (9 pin, D-Sub) | |
Environmental | Operating Temperature | -10°C to 80°C (14°F to 176°F) |
Storage Temperature | -20°C to 100°C (-4°F to 212°F) | |
Humidity | 5~85% RH | |
Hardware | Ports | 2 |
Interface | Parallel | |
Serial | ||
Bus Type | PCI / PCI-X (5 / 3.3V) | |
Card Type | Standard Profile (LP bracket incl.) | |
Port Style | Integrated on Card | |
Chipset ID | ASIX - MCS9835CV | |
Packaging Information | Package Height | 1.3 in [32 mm] |
Package Length | 5.7 in [14.5 cm] | |
Shipping (Package) Weight | 7.1 oz [200 g] | |
Package Width | 6.9 in [17.5 cm] | |
Performance | Maximum Data Transfer Rate | Up to 1.5 Mbits/sec. |
Serial Protocol | RS-232 | |
Max Baud Rate | 115.2 Kbps | |
FIFO | Serial: 32 Bytes Parallel: 16-Bytes |
|
Physical Characteristics | Weight of Product | 2.3 oz [66 g] |
Material | Steel | |
Product Length | 4.7 in [12 cm] | |
Product Width | 0.8 in [20 mm] | |
Product Height | 4.7 in [12 cm] | |
Software | OS Compatibility | Windows® DOS, 95, 98SE, 2000, CE 5.0 / 6.0, Embedded System 2009, XP Embedded, POS Ready 2009, XP, Vista, 7, 8, 8.1, 10 Windows Server® 2003, 2008 R2, 2012, 2016, 2019 Linux 3.5.x to 4.11.x LTS Versions only |
What's in the Box | 1 - Included in Package | PCI 2S1P Card |
DB9 Ribbon Cable | ||
3 - Included in Package | Low Profile Brackets | |
1 - Included in Package | Driver CD | |
Instruction Manual |
Connect your PC or dataswitch to a parallel printer
Connect a parallel printer to a PC or dataswitch
In stock: CA: 23 | US: 765
Extend your printer switchbox connections by 50ft
In stock: CA: 8 | US: 473
In stock: CA: 152 | US: 4694
In stock: CA: 73 | US: 1139
In stock: CA: 62 | US: 116
In stock: CA: 223 | US: 3817
Connect your serial devices, and transfer your files
In stock: CA: 149 | US: 2287
Convert a DB9 male connector to a DB25 male connector
In stock: CA: 71 | US: 2534
In stock: CA: 24 | US: 3499
In stock: CA: 77 | US: 913
Extend your EGA monitor cable or mouse cable by 6ft
In stock: CA: 77 | US: 2447
Connect your computer’s serial port to a modem or switchbox
In stock: CA: 92 | US: 555
We are always ready to assist you with any questions you may have.
Live Chat (opens in new window)We are always ready to assist you with any questions you may have.
Live Chat (opens in new window)Prior to installing this device, ensure that your operating system is up to date (for example, you have installed the most recent service pack).
To install the driver:
Note: Windows will typically save the files to the Downloads folder that is associated with your user account (for example, C:\Users\your_name\Downloads).
Note: If the Run as Administrator option is not available, you might be attempting to run the installer from within the zipped file. Extract the files using the instructions in Step 2.
Prior to installing this device, ensure that your operating system is up to date (for example, you have installed the most recent service pack).
To install the driver:
Note: Windows will typically save the files to the Downloads folder that is associated with your user account (for example, C:\Documents and Settings\your_name\My Documents\Downloads).
Before you install the device, make sure that your operating system is current (for example, the most recent service pack is installed).
Note: Windows usually saves the files to the Downloads folder that is associated with your user account (for example, C:\Users\your_name\Downloads).
Note: The Select your device’s type from the list below screen does not appear on all systems. If you do not see this screen, skip this step.
Note: To view your system type, press Windows key + R, type control /name microsoft.system, and press Enter.
Before you install the device, make sure that your operating system is current (for example, the most recent service pack is installed).
Note: Windows usually saves the files to the Downloads folder that is associated with your user account (for example, C:\Documents and Settings\your_name\My Documents\Downloads).
Note: The Hardware Type screen does not appear on all systems. If you do not see this screen, skip this step.
Note: To view your system type, press Windows key + R, type control /name microsoft.system, and press Enter.
Older applications that use serial communication often use legacy hardware addresses that do not work with PCI, PCIe, or USB to Serial products. We recommend contacting the software provider/support team to check if this is the case.
To check whether or not an RS-232 serial port is working, perform an RS-232 loopback test by doing the following:
Note: To open a telnet session on the COM port, you need a telnet client like PuTTY or Hyper Terminal. Windows XP comes with Hyper Terminal.
If the loopback test fails, make sure that the serial cable or gender changer that you are using works and that the adapter is in the correct port.
You can check multiple ports at the same time by opening multiple sessions, putting the loopback adapter on one port, and trying to type into each session. When you can see what you are typing, you know that the COM port is working and you can see which port number the physical serial port is. Close the window for the port that you just tested to speed up the testing of the remaining serial ports.
For products related to this article, click here.
When you troubleshoot issues with a serial or parallel hybrid device, there are some quick tests that you can complete to rule out potential problems. You can test to make sure that the following components are working correctly and are not the source of the issue:
Serial or parallel cables
Serial or parallel ports
Serial or parallel devices
To test your setup components, try the following:
Use the serial or parallel cable, serial or parallel port, and serial or parallel device in another setup to see if the problem is with the components or the setup.
Use a different serial or parallel cable, serial or parallel port, and serial or parallel device in your setup to see if the problem persists. Ideally, you should test a component that you know works in another setup.
When you test your cables, it is recommended that you do the following:
Test each cable individually.
Use short cables when you are testing.
When you test the serial or parallel ports and serial or parallel device, it is recommended that you do the following:
Press the Windows key + R, type devmgmt.msc, and press Enter to open Device Manager. Check to see if your device is listed under Ports (COM & LPT).
Make sure that the COM or LPT port number is the correct number for the serial or parallel device and that the software being used to connect the computer to the serial or parallel device uses the correct COM or LPT port number.
If you do not see the COM or LPT port number in Device Manager see this FAQ for PCI/PCIe expansion cards: https://www.startech.com/support/faqs/technical-support?topic=expansion-cards#pci-pcie-cannot-boot-os-or-detect-windows
or this FAQ for USB devices: https://www.startech.com/support/faqs/technical-support?topic=expansion-cards#usb-cannot-detect-windows
If the device is listed with an error, follow the instructions on the website to reinstall the drivers.
Note: Some serial devices work only if the COM or LPT port number is between a certain range. For example, COM1 to COM4 for serial and LPT1 and LPT2 for parallel.
Perform a serial loopback test. See this FAQ on how to perform a RS-232 serial loopback test: http://www.startech.com/faq/serial_loopback_test_rs232_windows
Note: There is not an equivalent loopback test that can be performed for parallel devices.
To confirm that Windows detects your expansion card, complete the following:
Your expansion card is listed according to the name of the chipset. To determine the name of the chipset of your expansion card, navigate to www.StarTech.com and look on the Technical Specifications tab for your product.
Yes. This PCI card uses a universal connector keyed for both 3.3V and 5V that can be used with PCI and PCI-X. This type of connector is identified as having 2 separate notches, instead of just one.
Check out our review guidelines.