USB 3.0/eSATA hyllfritt 3,5" SATA III hårddiskkabinett med två fack och UASP – 6 Gbps hot-swapbar HDD-kabinett med 2 fack

Anslut två hot-swapbara 3,5" SATA III-hårddiskar till datorn externt genom USB 3.0 med UASP eller eSATA

Produkt ID: S352BU33RER

  • Stöder SATA III (6 Gbps) och UASP (5 Gbps) för optimal prestanda
  • Hårdvaru-RAID med stöd för RAID 0 / RAID 1 / BIG / JBOD
  • Löstagbara hyllfria HDD-fack med enhetslås
Visa mer
  • Kompatibel med SATA-hårddiskar revision I/II/III (1,5/3,0/6,0 Gbps)
  • Kompatibel med USB 3.0/2.0/1.1 (5 Gbps / 480 Mbps / 1,5 Mbps)
  • Frontmonterad RAID-kontroller
  • USB 3.0- och eSATA-kablar medföljer
166,99 € EUR exkl. moms
208,74 € EUR inkl. moms
Inte tillgängligt
Kan finnas hos partners
Var kan jag köpa

Besök vår europeiska online-butik idag för fler produkter som denna!

Överblick

S352BU33RER RAID-kabinettet med 2 fack låter dig bygga en extern RAID-array med två 3,5” SATA-hårddiskar och ansluta till datorn genom USB 3.0 eller eSATA.

Kabinettet stöder SATA III-överföringshastigheter - upp till 6 Gbps vid anslutning genom eSATA, för snabb prestanda och effektiva dataöverföringar.  Det mångsidiga RAID-kabinettet kan även anslutas genom USB 3.0, med stöd för UASP, och presterar upp till 70 % snabbare än konventionell USB 3.0 vid användning med en UASP-kapabel värdkontroller. Se våra UASP-testresultat nedan för mer information.

Detta externa RAID-kabinett har en hårdvaru-RAID-kontroller med stöd för JBOD, Spanning, RAID 0 och RAID 1 -- för att öka enhetens kapacitet eller få säker dataredundans. RAID-kontrollern är dessutom frontmonterad för enkel åtkomst när du byter RAID-läge.

För snabb och enkel enhetsinstallation eller -frånkoppling har kabinettet för två hårddiskar ett praktiskt hyllfritt system som gör att du slipper montera och fästa enheterna och besparar dig tid och bekymmer.

För att garantera kompatibilitet med ditt datorsystem stöder S352BU33RER alla ledande operativsystem, inklusive: Microsoft Windows® (8/7/Vista/XP/Server 2008/Server 2003), Apple® OSX (10.9/10.8/10.7/10.6), Linux och Google Chrome OS™.

S352BU33RER täcks av StarTech.coms 2-årsgaranti och gratis livstidsgaranti på teknisk support.

Förbättrad prestanda med UASP

UASP stöds av Windows 8, Mac OSX (10.8 eller senare) och Linux. Vid tester ger UASP 70 % snabbare läshastigheter och 40 % snabbare skrivhastigheter över vanlig USB 3.0.

UASP Speed Diagram

Samtidigt visade UASP-testerna på 80 % reducerad åtgång av processorns resurser.

UASP Speed Diagram

Testerna utfördes med ett Intel® Ivy Bridge-system, ett UASP-kapabelt kabinett från StarTech.com och en SATA III solid state-enhet.

Fördelarna med StarTech.com

  • Mångsidiga anslutningsalternativ genom antingen USB eller eSATA
  • Maximera prestandan med filöverföringshastigheter på upp till 6 Gbps använda eSATA
  • Få större enhetskapacitet eller säker dataredundans med inbyggd hårdvaru-RAID-kontroller

Användning

Bygg en extern RAID 1-array för dataredundans och få skydd mot enhetsfel när du arbetar med viktig data

Arbeta externt och säkert med väldigt stora filer inom videoredigering eller fotografi

Överför stora datafiler snabbt från datorn till ett säkert externt RAID-kabinett

Tekniska specifikationer

Information om garanti
Garanti 2 Years
Hårdvara
Antal enheter 2
Antal interna 3,5 tums fack 2
Busstyp USB 3.0
Chipset-ID JMicron - JMS562
Enhetsinstallation Löstagbar
Enhetsstorlek 3.5in
Enhetstyp SATA
Fläkt(ar) Ja
Flaktar 1 - 70 mm
Fläktlagerstyp Glidlager
Gränssnitt USB 3.0 & eSATA
Nyckellås Ja
Prestanda
Bullernivå 26.24 dBa
Hot swap-förmåga Ja
Luftflödeshastighet 12.72 CFM
Maximal dataöverföringshastighet 6 Gbps
Maximal enhetskapacitet För närvarande testad med upp till 4 TB 7200 RPM 3,5" hårddiskar per fack (totalt 8 TB) och 2TB 5900 RPM 2,5"-hårddiskar (totalt 2 TB)
Port Multiplier Ja
RAID Ja
RAID-lägen som stöds BIG (Omfång eller sammanfogning)
JBOD - (Just a Bunch of Disks)
RAID 0 (stripade enheter)
RAID 1 (speglade enheter)
Typ och hastighet USB 3.0 - 5 Gbit/s
SATA III (6 Gbps)
UASP-stöd Ja
Kontakt(er)
Enhetskontakter 2 - SATA data- & ström-kombo (7+15-stifts) Honuttag
Värdkontakter 1 - USB Type-B (9-stifts) USB 3.0 Hona
1 - eSATA (7-stifts, data) Hona
Mjukvara
OS-kompatibilitet OS independent; No software or drivers required
Indikatorer
LED-indikatorer 1 - HDD 1-aktivitet
1 - HDD 2-aktivitet
1 - RAID-LED
Ström
Inspänning 110V-240V AC
Power Source AC-adapter medföljer
Strömförbrukning 36
Utspänning 12 DC
Utström 3 A
Miljö
Drifttemperatur 5°C to 35°C (41°F to 95°F)
Förvaringstemperatur -20°C to 50°C (-4°F to 122°F)
Luftfuktighet 20 %~80 % RH
Utseende
Produktbredd 130 mm [5.1 in]
Produkthöjd 118 mm [4.6 in]
Produktlängd 215 mm [8.5 in]
Produktvikt 1834 g [64.7 oz]
Förpackning
Fraktvikt (förpackning) 2.9 kg [6.3 lb]
Vad det är i lådan
Ingår i paketet 1 - USB 3.0/eSATA dubbel 3,5" SATA HDD hyllfritt kabinett
1 - eSATA-kabel
1 - USB 3.0-kabel
2 - Nycklar till enhetsfack
1 - Universell strömadapter (NA/UK/EU)
1 - Instruktionsbok

Kompatibilitet

Se alla kompatibla operativsystem
OS independent; No software or drivers required

Certifikat

Tillbehör

Produktsupport

Vanliga frågor

Before You Buy

To determine if your hard drive will work in this enclosure, on the product page, click the Technical Specifications tab, and do the following:

  • Make sure that the enclosure supports the storage size of your hard drive. If the storage size of your hard drive is larger than what the enclosure was tested with, the hard drive will likely still work with the enclosure.
  • Confirm that your hard drive uses the same interface type as the enclosure. For example, IDE, SATA, or M.2.
  • Make sure that the enclosure supports the physical size of your hard drive, such as 2.5 inches or 3.5 inches.
  • Make sure that the enclosure supports the height of your hard drive. For example, 9 mm or 15 mm.
  • Verify that the power consumption of your hard drive doesn’t exceed the power output of the enclosure. If you’re using multiple hard drives, make sure that the combined power consumption of all of the hard drives doesn’t exceed the power output of the enclosure.

Note: Not all StarTech.com devices support each of the RAID modes described below. For more information on the RAID modes that your device supports, refer to the manual or the StarTech.com product page.

Redundant Array of Independent Disks (RAID) is a virtual disk technology that combines multiple physical drives into one unit. RAID can create redundancy, improve performance, or do both.

RAID should not be considered a replacement for backing up your data. If critical data is going onto a RAID array, it should be backed up to another physical drive or logical set of drives.

The following are terms that are normally used in connection with RAID:

  • Striping: data is split between multiple disks.
  • Mirroring: data is mirrored between multiple disks.
  • Parity: also referred to as a checksum. Parity is a calculated value used to mathematically rebuild data.

Different RAID levels exist for different application requirements.

Refer to the following table for the list of RAID modes offered by some StarTech.com products:

RAID mode Description Operation Advantages Disadvantages Recovery
RAID 0 Striped disks Data is split evenly between two or more disks. Large size and the fastest speed. No redundancy. If one or more drives fails, this results in array failure.
RAID 1 Mirrored disks Two or more drives have identical data on them. A single drive failure will not result in data loss. Speed and size is limited by the slowest and smallest disk. Only one drive is needed for recovery.
RAID 3 Striped set with dedicated parity Data is split evenly between two or more disks, plus a dedicated drive for parity storage. High speeds for sequential read/write operations. Poor performance for multiple simultaneous instructions. A single drive failure will rebuild.
RAID 5 Striped disks with distributed parity Data is split evenly between three or more disks. Parity is split between disks. Large size, fast speed, and redundancy. The total array size is reduced by parity. A single drive failure will rebuild.
RAID 10 1+0; Striped set of Mirrored Subset Four or more drives are made into two mirrors that are striped. Larger size and higher speed than RAID-1, and more redundancy than RAID-0. No parity. Only one drive in a mirrored set can fail.
JBOD Just a Bunch Of Disks Any number of drives are accessed independently by the operating system. Software RAID modes can be used. Hardware RAID may have better performance. N/A
Big Spanning or Concatenation Data is written on one drive until it is full, and then the next drive(s) until it or they are full. Creates a very large and simple array.

No redundancy.

N/A
Clone RAID 1 + Spare

Two drives have identical data, plus one drive is used for rebuilding in case of a primary array failure.

Seamless operation when one drive fails in a RAID-1 array. Spare drive is not accessible to the user. Only one drive is needed for recovery.

 

Hur man

To confirm that the Mac OS detects your USB device, complete the following:

  1. Click the Apple icon.
  2. Click About This Mac.
  3. Click More Info or System Report.
  4. Under the appropriate heading, confirm that your USB device is listed and that there isn't an error. For example, a network card would be under Ethernet Cards.

You may need to refresh the System Information page after you plug in your device.  To do so, press Command R with the System Information page open.

Your USB device is listed according to the name of the chipset. To determine the name of the chipset of your USB device, navigate to www.StarTech.com and look on the Technical Specifications tab for your product.

Problemsökning

SATA hard drive controllers require a feature called port multiplier to read more than one hard drive per SATA or eSATA port. The port multiplier feature is not standard on many SATA hard drive controllers.

If your computer is only recognizing one of your hard drives, you need to plug the eSATA cable into a SATA controller that includes the port multiplier feature. If none of your current hard drive controllers include this feature, you can add a hard drive controller that does support port multiplier in any available expansion slot (for example, PCI, PCI-Express, PCMCIA, CardBus, or ExpressCard). StarTech.com has hard drive controllers available that support the port multiplier feature. To view the hard drive controllers, click here: http://startech.com/Cards-Adapters/HDD-Controllers/SATA-Cards/?filter_PORTMULTIPLIER=Yes.

If you have a hard drive controller card that does support the port multiplier feature but it is only reading one hard drive at a time, update the drivers of the hard drive controller. To find the most current StarTech.com drivers, click here: http://www.startech.com/Support.

When you troubleshoot issues with a hard drive enclosure, there are some quick tests that you can complete to rule out potential problems. You can test to make sure that the following components are working correctly and are not the source of the issue:

  • Cables
  • Hard drives
  • Hard drive enclosure

To test your setup components, try the following:

  • Use the cables, hard drives, and hard drive enclosure in another setup to see if the problem is with the components or the setup.
  • Use a different cable, hard drive, and hard drive enclosure in your setup to see if the problem persists. Ideally, you should test a component that you know works in another setup.

When you test the hard drive and hard drive enclosure, it is recommended that you do the following:

  • To check Disk Management, press the Windows key + R, type diskmgmt.msc, and press Enter. Check to see if your hard drive is listed.
  • If the hard drive is listed with unallocated space, the hard drive needs to be reformatted. Right-click unallocated and click New Simple Volume. Follow the on-screen instructions to complete the reformatting.​

Note: Formatting a hard drive erases all of the data on it. Make sure that you back up all of your data before you reformat the hard drive.​

  • If the hard drive is listed as healthy but does not have a drive letter, for example, C:, right-click healthy and click Change Drive Letter and Paths. Click Add, assign a drive letter, and click OK.

Note: A formatted hard drive will not show up in Computer or My Computer until it has a drive letter assigned to it.

In order to rebuild a RAID array, you need to replace a physical drive with an identical drive on the same RAID controller. Although standard RAID levels are generally agreed upon throughout the industry, the implementation varies between manufacturers. RAID arrays are typically not accessible when they are moved to another controller, and data may be unrecoverable if the drives are out of order or have been formatted or accessed by another RAID controller.

If a RAID controller has failed, you should get the exact same model of RAID controller.  

Note: If a drive or drives were damaged, it is possible that the RAID array may be permanently unrecoverable.

RAID should not be considered a replacement for backing up your data. If critical data is going onto a RAID array, you should back up the data on another physical drive or logical set of drives.

Rebuild a RAID array

With the following RAID modes, recovery is possible using the same StarTech.com product. Refer to the following table for the appropriate method to use to recover your RAID array.

RAID mode Max # of failed drives Procedure
RAID 1 Only one drive is needed for recovery.
  1. Determine which drive is operational by using the RAID management utility (if available) or test each drive individually on a different hard drive controller (for example, a hard drive docking station or SATA controller).

  2. Replace the failed drive with an identical hard drive.

The array will rebuild and is accessible during the rebuilding process.

RAID 3 Single drive failure will rebuild.
  1. Determine which drive is defective by using the RAID management utility (if available) or with diagnosis LEDs on the controller or enclosure.

  2. Replace with an identical hard drive.

Note: Do not change the order of the drives.

  1. The array may be accessible during the rebuild, but you should let the controller rebuild without interruption so that performance is not compromised.

RAID 5 Single drive failure will rebuild.
  1. Determine which drive is defective by using the RAID management utility (if available) or with diagnosis LEDs on the controller or enclosure.

  2. Replace with an identical hard drive.

Note: Do not change the order of the drives.

  1. The array may be accessible during the rebuild, but you should let the controller rebuild without interruption so that performance is not compromised.

RAID 10 Only one drive in a mirrored set can fail.
  1. Determine which drive is defective by using the RAID management utility (if available) or with diagnosis LEDs on the controller or enclosure.

  2. Replace with an identical hard drive.

Note: Do not change the order of the drives.

  1. The array may be accessible during the rebuild, but you should let the controller rebuild without interruption so that performance is not compromised.