Value 1 Port PCI Parallel Adapter Card

Add a parallel port to your desktop computer through a PCI expansion slot

Produkt ID: PCI1P

  • Supports EPP, ECP, SPP and BPP
  • Data transfer rates of up to 2.7 Mbits/sec maximizes the performance of your peripherals
  • IRQ sharing eliminates conflicts between multiple cards

The PCI1P value priced EPP/ECP parallel card adds one IEEE 1284 port to your PC, with data transfer speeds of up to 2.7 Mbps – up to 3 times faster than on-board parallel ports.

Installation is a breeze with plug and play support and drivers for Windows® 7, Vista, XP, ME, 2000, 98, 95, NT4, DOS® and Linux®. IRQ sharing and hot swapping capabilities guarantee convenient, hassle-free connections to any parallel peripheral.

Backed by a StarTech.com lifetime warranty and free lifetime technical support.

Användning

  • Connects any parallel peripheral including printers, scanners, CD-R/RWs, Zip® drives, and memory card readers

Fördelarna med StarTech.com

  • Up to 3 times faster than legacy ISA or on-board parallel ports providing fast and reliable parallel communication
  • Supports SPP, EPP, ECP and BPP communication modes for maximum compatibility with your parallel peripherals
  • Guaranteed compatibility with any PC running Windows®, Linux® or DOS® for simple integration into your application

Partnernummer

  • UPC 065030781992

Kompatibilitet

  • Windows 8 logo
  • Windows 7 logo
  • Linux logo
Windows® DOS, 95, 98SE, ME, XP, Vista, 7, 8, 8.1, 10
Linux 3.5.x to 4.4.x LTS Versions only

Specifikationer

Warranty Information Warranty Lifetime
Förpackning Package Length 21 cm [8,3 in]
Package Width 38 mm [1,5 in]
Package Height 14,3 cm [5,6 in]
Fraktvikt (förpackning) 160 g [5,6 oz]
Hårdvara Portar 1
Gränssnitt Parallell
Busstyp PCI / PCI-X (5 / 3.3V)
Korttyp Standardprofil
Porttyp Inbyggd på kort
Industristandarder IEEE-1284
Chipset-ID Sunix - SUN1888
Kontakt(er) 1 - Kontakttyp(er) PCI/PCI-X (universell 3,3 & 5 V, 32-bitars)
1 - Externa portar DB-25 (25-stifts, D-Sub)
Mjukvara OS-kompatibilitet Windows® DOS, 95, 98SE, ME, XP, Vista, 7, 8, 8.1, 10
Linux 3.5.x to 4.4.x LTS Versions only
Microsoft WHQL-certifierad Ja
Prestanda Maximal dataöverföringshastighet 2.7Mbps
Stödda protokoll EPP, ECP, SPP, BPP
Särskilda anmärkningar/krav System- och kabelkrav Unused PCI slot
Utseende Produktlängd 12 cm [4,7 in]
Produkthöjd 55 mm [2,2 in]
Vad det är i lådan 1 - Ingår i paketet 1 Port PCI Parallel Card
Driver CD
User Manual

Tillbehör

Utgått
PB10

3 m DB25 till Centronics 36 parallellskrivarkabel - M/M

Anslut din PC-dator eller dataswitch till en parallellskrivare

Ditt pris
€7,99 EUR excl. VAT
€9,99 EUR incl. VAT
PB6_

6 ft DB25 to Centronics 36 Parallel Printer Cable - M/M

Connect a parallel printer to a PC or dataswitch

Ditt pris
€5,99 EUR excl. VAT
€7,49 EUR incl. VAT
Utgått
Ditt pris
€5,99 EUR excl. VAT
€7,49 EUR incl. VAT
Ditt pris
€5,99 EUR excl. VAT
€7,49 EUR incl. VAT

Drivers/Downloads

Prata med en rådgivare.

Vi är alltid redo att hjälpa dig med alla dina frågor.

Direktchatt (opens in new window)

Drivrutin(er):

Manual(er):

Datasheet

Produktsupport

Prata med en rådgivare.

Vi är alltid redo att hjälpa dig med alla dina frågor.

Direktchatt (opens in new window)

Vanliga frågor

Installation

Before you install the driver, make sure that your operating system is current (for example, the most recent service pack is installed).

  1. Download the latest drivers from the StarTech.com website at http://www.startech.com/Support. The part number and product ID are on the product packaging.

Note: Windows usually saves the files to the Downloads folder that is associated with your user account (for example, C:\Documents and Settings\your_name\My Documents\Downloads).

  1. After the download is complete, right-click the zip folder that you downloaded, click Extract All, and complete the instructions.
  2. In the list of extracted files, double-click the Setup.exe file.
  3. Complete the instructions to install the device drivers, and restart your computer when prompted to.

Your computer will automatically complete the driver installation and your device should be ready to use.

Problemsökning

When you troubleshoot issues with a parallel device, there are some quick tests that you can complete to rule out potential problems. You can test to make sure that the following components are working correctly and are not the source of the issue:

  • Parallel cables

  • Parallel ports

  • Parallel devices

To test your setup components, try the following:

  • Use the parallel cable, parallel port, and parallel device in another setup to see if the problem is with the components or the setup.

  • Use a different parallel cable, parallel port, and parallel device in your setup to see if the problem persists. Ideally, you should test a component that you know works in another setup.

When you test your cables, it is recommended that you do the following:

  • Test each cable individually.

  • Use short cables when you are testing.

When you test the parallel ports and parallel device, it is recommended that you do the following:

Note: Some parallel devices only work if the LPT port number is between a certain range, usually LPT1 or LPT2.

Hur man

To confirm that Windows detects your expansion card, complete the following:

  1. Press the Windows key+R, type devmgmt.msc, and press Enter.
  2. In Device Manager, under the appropriate heading, confirm that your expansion card is listed and that there isn't an exclamation mark next to it.  For example, a USB controller card would be under Universal Serial Bus controllers.

Your expansion card is listed according to the name of the chipset. To determine the name of the chipset of your expansion card, navigate to www.StarTech.com and look on the Technical Specifications tab for your product.

Compliance and safety

Compliance letters

  • RoHS
    • Språk: English
  • WEEE
    • Språk: English

Safety Measures

  • If product has an exposed circuit board, do not touch the product under power.
  • If Class 1 Laser Product. Laser radiation is present when the system is open.
  • Wiring terminations should not be made with the product and/or electric lines under power.
  • Product installation and/or mounting should be completed by a certified professional as per the local safety and building code guidelines.
  • Cables (including power and charging cables) should be placed and routed to avoid creating electric, tripping or safety hazards.