Utgått

8 Port PCI Express Low Profile Serial Adapter Card

Add 8 RS-232 serial ports to your computer via a single low profile PCI Express slot

Produkt ID: PEX8S950LP

  • 8 RS232 DB9 connections using a single PCI Express slot
  • Breakout cables included
  • Provides you with mounting brackets for low profile and standard cases

The PEX8S950LP 8 Port PCI Express Low Profile Serial Adapter Card with dongle cables included offers 8 RS 232 Serial connections via a single PCI Express slot, with data rates up to 921Kbps. Perfect for use with a broad variety of serial peripherals including printers, scanners, industrial controls and more.

A complete 8 port RS232 Serial card solution, the adapter includes 2 breakout cables – each with 4 DB9 connectors for a total of 8 ports. The perfect choice for adding several additional ports when space is at a premium, the serial adapter card is designed to fit in small/micro form factor computer cases. Plus, this versatile card also includes 2 standard profile brackets for compatibility with full size cases.

Backed by a StarTech.com Lifetime warranty and free lifetime technical support.

Användning

  • Manufacturing (CNC machinery, process control equipment, bar code scanners, serial printers)
  • POS (credit/debit card readers, receipt printers, bar code scanners, cash registers, scales)
  • Consumer (modems, PDAs, digital cameras, printers)
  • Security (UPS control, access key panels, video cameras, card readers, modems)
  • Casino (video lottery terminals, slot machines)
  • Environmental Control (lighting, temperature, clocks)
  • Healthcare (patient monitoring equipment, nurses' stations, modems)
  • Hotel Front Desk (serial printers, bar code scanners, keyboard, mouse, receipt printer, credit/debit card reader)
  • Hospitality/Restaurant (credit card/debit card reader, serial printers)
  • ISDN Networking

Fördelarna med StarTech.com

  • Includes 2 breakout cables, helping to avoid crowded connections
  • Pre-configured with low profile brackets and ships complete with 2 standard profile brackets for compatibility with almost any computer case
  • Easy to install and use with full step-by-step instructions for hassle-free integration into your system

Partnernummer

  • Ingram Micro Sweden V930871
  • ALSO Sweden 000000000002775976
  • UPC 065030825108

Kompatibilitet

  • Windows 8 logo
  • Linux logo
  • Windows Server 2012 logo
  • Windows 7 logo
  • Windows 10 logo
  • Windows Server 2016 logo
  • Windows Server 2019 logo
Windows® CE 5.0, 98SE, 2000, XP, Vista, 7, 8, 8.1, 10
Windows Server® 2003, 2008 R2, 2012, 2016, 2019
Linux 2.4.x till 4.11.x Endast LTS-versioner

Specifikationer

Warranty Information Warranty Lifetime
Förpackning Package Length 0 mm [0,0 in]
Package Width 0 mm [0,0 in]
Package Height 0 mm [0,0 in]
Fraktvikt (förpackning) 0 g [0,0 oz]
Hårdvara Portar 8
Gränssnitt Seriell
Busstyp PCI Express
Korttyp Lågprofil (SP-fästen ingår)
Porttyp Dongel (medföljer)
Chipset-ID PLX/Oxford - OXmPCI952
Kontakt(er) 1 - Kontakttyp(er) PCI Express x1
8 - Externa portar DB-9 (9-stifts, D-Sub)
Miljö Drifttemperatur 0°C to 55°C (32°F to 131°F)
Förvaringstemperatur -20°C to 85°C (-4°F to 185°F)
Luftfuktighet 5~95% RH
Mjukvara OS-kompatibilitet Windows® CE 5.0, 98SE, 2000, XP, Vista, 7, 8, 8.1, 10
Windows Server® 2003, 2008 R2, 2012, 2016, 2019
Linux 2.4.x till 4.11.x Endast LTS-versioner
Prestanda Seriellt protokoll RS-232
Maximal överföringshastighet 921,6 kbps
Databitar 5, 6, 7, 8, 9
FIFO 128 Bytes
Flödeskontroll RTS/CTS, XON/XOFF
Paritet None, Even, Odd, 1, 0
Stoppbitar 1, 1.5, 2
Utseende Kabellängd 28 cm [11,0 in]
Produktlängd 0 mm [0,0 in]
Produktbredd 0 mm [0,0 in]
Produkthöjd 0 mm [0,0 in]
Produktvikt 0 g [0,0 oz]
Vad det är i lådan 1 - Ingår i paketet 8 Port PCI Express Serial Card
2 - Ingår i paketet Breakout Cables
Standard Brackets
16 - Ingår i paketet Löstagbara sexkantsmuttrar
1 - Ingår i paketet Driver CD
Instruction Manual

Tillbehör

AT925FM

DB9 till DB25 seriell kabeladapter - F/M

Konvertera en DB9-hanport till en DB25-hanport

Ditt pris
€2,99 EUR excl. VAT
€3,74 EUR incl. VAT
AT925FF

DB9 to DB25 Serial Cable Adapter - F/F

Convert a DB9 male port to a DB25 female port

Ditt pris
€2,99 EUR excl. VAT
€3,74 EUR incl. VAT
SCNM9FM

3 m seriell DB9 RS232 nollmodemskabel F/M

Överför filer via en seriell anslutning

Ditt pris
€4,99 EUR excl. VAT
€6,24 EUR incl. VAT
Ditt pris
€9,99 EUR excl. VAT
€12,49 EUR incl. VAT
SCNM9FF

3 m DB9 RS232 seriell nollmodemskabel F/F

Överför filer via en seriell anslutning

Ditt pris
€5,99 EUR excl. VAT
€7,49 EUR incl. VAT
SCNM925FM

3 m Seriell korsad DB9 till DB25-nollmodemskabel - F/M

Anslut dina seriella enheter och för över dina filer

Ditt pris
€4,99 EUR excl. VAT
€6,24 EUR incl. VAT

Drivers/Downloads

Prata med en rådgivare.

Vi är alltid redo att hjälpa dig med alla dina frågor.

Direktchatt (opens in new window)

Manual(er):

Datasheet

Produktsupport

Prata med en rådgivare.

Vi är alltid redo att hjälpa dig med alla dina frågor.

Direktchatt (opens in new window)

Vanliga frågor

Installation

Before you install the device, make sure that your operating system is current (for example, the most recent service pack is installed).

  1. Download the latest drivers from the StarTech.com website at http://www.startech.com/Support. The part number and product ID are on the product packaging.

Note: Windows usually saves the files to the Downloads folder that is associated with your user account (for example, C:\Users\your_name\Downloads).

  1. After the download is complete, right-click the zip folder that you downloaded, click Extract All, and complete the instructions.
  2. Press the Windows key + R, type devmgmt.msc, and press Enter to open the Device Manager.
  3. Right-click PCI Serial Port, which will have a “!” or “?” next to it to indicate a driver issue.
  4. Click Update Driver.
  5. Click Browse my computer for driver software.
  6. Select the Let me pick from a list of device drivers on my computer option.
  7. On the Select your device’s type from the list below screen, click Show All Devices, and click Next.

Note: The Select your device’s type from the list below screen does not appear on all systems. If you do not see this screen, skip this step.

  1. Select the Have Disk option.
  2. Browse to the Windows folder, select the folder for your operating system, and open the 32-bit or the 64-bit folder, depending on your system type.

Note: To view your system type, click Start. Right-click Computer, and then click Properties.

  1. Click the OxMf or OxPCIeMf file. Click OK, and then click Next.

Note: If you are using a serial card that uses the OxPCIeMf file and installation fails, repeat steps 4 to 9, then browse to the Windows folder. Browse to the Serial Port Driver folder and click the oxserleg file.  Click OK, and then click Next.

Before you install the device, make sure that your operating system is current (for example, the most recent service pack is installed).

  1. Download the latest drivers from the StarTech.com website at http://www.startech.com/Support. The part number and product ID are on the product packaging.

Note: Windows usually saves the files to the Downloads folder that is associated with your user account (for example, C:\Documents and Settings\your_name\My Documents\Downloads).

  1. After the download is complete, right-click the zip folder that you downloaded, click Extract All, and complete the instructions.
  2. Press the Windows key + R, type devmgmt.msc, and press Enter to open the Device Manager.
  3. Right-click PCI Serial Port, which will have “!” or “?” next to it to indicate a driver issue.
  4. Click Update Driver.
  5. On the Hardware Update Wizard screen, click Install from a list or specific location (Advanced), and then click Next.
  6. Select the Don’t search, I will choose the driver to install option, and then click Next.
  7. On the Hardware Type screen, click Show All Devices, and then click Next.

Note: The Hardware Type screen does not appear on all systems. If you do not see this screen, skip this step.

  1. On the Select the Device Driver you want to install for this hardware screen, select the Have Disk option.
  2. In the Install from Disk dialog box, click Browse.
  3. Browse to the Windows folder, select the folder for your operating system, and open the 32-bit or the 64-bit folder, depending on your system type.

Note: To view your system type, click Start. Right-click Computer, and then click Properties.

  1. Click the OxMf or OxPCIeMf file. Click OK, and then click Next.

Note: If you are using a serial card that uses the OxPCIeMf file and installation fails, repeat steps 4 to 10, then browse to the Windows folder. Browse to the Serial Port Driver folder and click the oxserleg file.  Click OK, and then click Next.

Problemsökning

When you troubleshoot issues with a serial device, there are some quick tests that you can complete to rule out potential problems. You can test to make sure that the following components are working correctly and are not the source of the issue:

  • Serial cables

  • Serial ports

  • Serial devices

To test your setup components, try the following:

  • Use the serial cable, serial port, and serial device in another setup to see if the problem is with the components or the setup.

  • Use a different serial cable, serial port, and serial device in your setup to see if the problem persists. Ideally, you should test a component that you know works in another setup.

When you test your cables, it is recommended that you do the following:

  • Test each cable individually.

  • Use short cables when you are testing.

When you test the serial ports and serial device, it is recommended that you do the following:

Note: Some serial devices work only if the COM port number is between a certain range. For example, COM1 to COM4.

To check whether or not an RS-232 serial port is working, perform an RS-232 loopback test by doing the following:

  1. If your serial port is not female, convert it by taking a female/female cable or gender changer and plugging it into the serial port.
  2. Take a metal paperclip or wire and cross pins 2 and 3. If you look closely at the female end, the pins should be numbered.
  3. Open a telnet session on the COM port number of the device that you are testing. To find out the COM port number, refer to the following FAQ: https://www.startech.com/faq/com-port-listing-windows.

Note: To open a telnet session on the COM port, you need a telnet client like PuTTY or Hyper Terminal. Windows XP comes with Hyper Terminal.

  1. When the session is open, anything you type into it you should see. The loopback test fails when you cannot see what you are typing.

If the loopback test fails, make sure that the serial cable or gender changer that you are using works and that the adapter is in the correct port. 

You can check multiple ports at the same time by opening multiple sessions, putting the loopback adapter on one port, and trying to type into each session.  When you can see what you are typing, you know that the COM port is working and you can see which port number the physical serial port is. Close the window for the port that you just tested to speed up the testing of the remaining serial ports.

Hur man

To confirm that Windows detects your expansion card, complete the following:

  1. Press the Windows key+R, type devmgmt.msc, and press Enter.
  2. In Device Manager, under the appropriate heading, confirm that your expansion card is listed and that there isn't an exclamation mark next to it.  For example, a USB controller card would be under Universal Serial Bus controllers.

Your expansion card is listed according to the name of the chipset. To determine the name of the chipset of your expansion card, navigate to www.StarTech.com and look on the Technical Specifications tab for your product.

Compliance and safety

Compliance letters

  • RoHS
    • Språk: English
  • WEEE
    • Språk: English

Safety Measures

  • If product has an exposed circuit board, do not touch the product under power.
  • If Class 1 Laser Product. Laser radiation is present when the system is open.
  • Wiring terminations should not be made with the product and/or electric lines under power.
  • Product installation and/or mounting should be completed by a certified professional as per the local safety and building code guidelines.
  • Cables (including power and charging cables) should be placed and routed to avoid creating electric, tripping or safety hazards.
* Produkters utseende och specifikationer kan komma att ändras utan förvarning.
Tillbaka till toppen