10/100 Multi Mode Fiber Copper Fast Ethernet Media Converter ST 2 km

Convert and extend a 10/100 Mbps Ethernet connection up to 2 km over Multi Mode ST fiber

Produkt ID: MCM110ST2EU

  • Supports a maximum multi mode fiber optic cable distance of 2 km
  • Supports full or half-duplex operation
  • Compatible with 3COM™, Cisco™, Lucent™ and Nortel™ networks
Ditt pris
€94,99 EUR excl. VAT
€118,74 EUR incl. VAT

The MCM110ST2EU 10/100 Multi Mode ST Fiber Ethernet Media Converter (2 km) creates a cost-effective Ethernet to fiber link, transparently converting to/from 10Base-T or 100Base-Tx Ethernet signals and 100Base-Fx optical signals to extend an Ethernet network connection over a multimode fiber backbone.

The ST media converter supports a maximum multimode fiber optic cable distance of 2km (1.2 miles), providing a simple solution for connecting 10Base-T/100Base-Tx Ethernet networks to remote locations using ST-terminated multimode fiber, while delivering solid network performance and scalability.

Easy to setup and install, this compact, value-conscious fast Ethernet media converter features auto-switching MDI and MDI-X support on the RJ45 UTP connections as well as manual controls for UTP mode, speed, Full and Half Duplex, as well as LFP (Link Fault pass-through) on/off.

Backed by a StarTech.com 2-year warranty and free lifetime technical support.

Användning

  • Provides connectivity to a user or network segment that is in an isolated area of a large complex or in another building altogether
  • Perfect for secure environments required by government agencies where EMI is not acceptable
  • Connect traffic control/monitoring systems at extreme distances to the main office
  • Extend network connectivity to remote areas of stadiums, auditoriums or other venues
  • Converts 10/100Base-T Ethernet to 100Base-FX fiber optic signals over multimode fiber cable

Fördelarna med StarTech.com

  • Improve network scalability by increasing the distances between network points by up to 2km (Multi-mode)
  • Compact, lightweight enclosure is easily mounted or placed into any location with little to no configuration needed
  • Provides increased bandwidth and high data throughput by eliminating network bottlenecks and congestion

Partnernummer

  • UPC 065030836845

Specifikationer

Warranty Information Warranty 2 Years
Förpackning Package Length 14,5 cm [5,7 in]
Package Width 17,5 cm [6,9 in]
Package Height 65 mm [2,6 in]
Fraktvikt (förpackning) 0,3 kg [0,6 lb]
Hårdvara PoE Nej
WDM Nej
Industristandarder IEEE 802.3u 100BASE-FX
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
Indikatorer 1 - LED-indikatorer FEF [Far End Fault](On - Fault Detected, Off - No Fault)
Ethernet Link & Activity (ON - Fiber Link ok, Blinking - Activity on Fiber Link)
Fiber Link & Activity (On - Fiber Link ok, Blinking - Activity on Fiber Link)
Full ( Full duplex / Half duplex)
Power
Speed (10 or 100 Mbps)
Kontakt(er) 1 - Lokala enhetskontakter RJ-45
Fiberoptisk ST duplex
Miljö Drifttemperatur 0°C to 50°C (32°F to 122°F)
Förvaringstemperatur -10°C to 70°C (14°F to 158°F)
Luftfuktighet 10~90% RH
Prestanda Maximal dataöverföringshastighet 10/100Mbps
Maximalt överföringsavstånd 2 km (1.2 mi)
Fibertyp Multiläge
Våglängd 1310nm
Fiber-driftsläge Halv/full-duplex
Optisk Effekt -14 ~ -20 dBm
Känslighet -31 dBm
Effektbudget 11 dB
Medeltid mellan fel (MTBF) 65,000 Hours
Ström Power Source AC-adapter medföljer
Inspänning 100 - 240 AC
Utspänning 12V DC
Utström 0.2A
Polaritet på mittpol Positiv
Kontakttyp M
Strömförbrukning 2.4
Utseende Färg Svart
Kabinettyp Av plast
Produktlängd 75 mm [3,0 in]
Produktbredd 95 mm [3,7 in]
Produkthöjd 2 cm [0,8 in]
Produktvikt 90,5 g [3,2 oz]
Vad det är i lådan 1 - Ingår i paketet Media Converter
Power Adapter
Instruction Manual

Tillbehör

SVA12M2NEUA

DC-strömadapter - 12 V, 2 A

Byt ut din borttappade eller trasiga strömadapter

Ditt pris
€25,99 EUR excl. VAT
€32,49 EUR incl. VAT
SVA12M5NA

DC-strömadapter - 12 V, 5 A

Byt ut din borttappade eller trasiga strömadapter

Ditt pris
€65,99 EUR excl. VAT
€82,49 EUR incl. VAT

Drivers/Downloads

Prata med en rådgivare.

Vi är alltid redo att hjälpa dig med alla dina frågor.

Direktchatt (opens in new window)

Manual(er):

Datasheet

Produktsupport

Prata med en rådgivare.

Vi är alltid redo att hjälpa dig med alla dina frågor.

Direktchatt (opens in new window)

Vanliga frågor

Problemsökning

When you troubleshoot issues with a fiber media converter, there are some quick tests that you can complete to rule out potential problems. To identify what the source of the issue is, observe the power LED, LAN LEDs, and fiber link LED on the units.

If the power LED is not illuminated for the transmitter or the receiver, complete the following:

  • Make sure that you are using the provided power adapter(s).

  • Make sure that the adapter is plugged into a compatible wall outlet.

  • Make sure that the adapter is plugged into both the transmitter and receiver.

If another LED is not operating as expected, make sure that the components in your setup are working correctly. To test your setup components, try the following:

  • Use the cables, fiber media converter, and network devices (including SFPs, if applicable) in another setup to see if the problem is with the components or the setup.

  • Use different cables, fiber media converter, and network devices (including SFPs, if applicable) in your setup to see if the problem persists. Ideally, you should test components that you know work in another setup.

When you test your cables, it is recommended that you do the following:

  • Test each cable individually.

  • Use short cables when you are testing.

Make sure that the DIP switches are set to the following:

  • DIP switches should be identical on both local and remote units. By default, DIP switches are set to Off (the switch is pointing up).

  • For more information about the advanced configuration options, refer to the manual for your product.

If you cannot establish a network connection between your local and remote units, you need to do the following to make sure that the issue is not related to the network configuration:

  • Use two computer systems directly connected to the fiber media converter LAN ports.

  • Open a command prompt on Computer 1 and ping Computer 2.

If the issue is not related to the network configuration, you should receive a response from Computer 2.

 

For more information on how to ping another network device, refer to the following FAQ: https://www.startech.com/support/faqs/technical-support?topic=networking#ping-test-windows-mac-os.

Before You Buy

Different optical cables are needed for different applications. Before you select a cable to interconnect fiber devices, make sure that the following things match:

  • Mode: Single Mode or Multi Mode.

  • Wavelength: For example, 850 nm, 1310 nm, or 1550 nm.

Note: The above properties cannot be converted or changed by a cable.

When you select a cable, make sure that the cable ends (for example, LC, SC, ST, or MT) match the fiber media devices.

Simplex and duplex ends are available for most connector types. Simplex cables have the connectors separate, where duplex cables have the transmit (TX) and receive (RX) connectors joined together.  StarTech.com fiber media devices are compatible with simplex and duplex connectors.

It does not matter which diameter or OM classification the cable uses, as long as it meets the mode requirement.

Fiber media converters can be used to convert a standard Ethernet connection to a standard fiber connection, or can be used to extend a copper Ethernet network. When you use fiber media converters to extend a copper Ethernet network, make sure that the same fiber standards are being used on either end of the fiber network.

UPC and APC are fiber cable connector types. UPC (Ultra Physical Contact) connectors have a fiber connector end face that has been polished to be dome-shaped. This results in light that can be reflected straight back to the source.

APC (Angled Physical Contact) connectors have a fiber connector end face that has been polished at an eight degree angle. This results in a reduced amount of light that is reflected between the two connected fibers.

StarTech.com fiber cables use UPC connectors.

Compliance and safety

Compliance letters

Safety Measures

  • If product has an exposed circuit board, do not touch the product under power.
  • If Class 1 Laser Product. Laser radiation is present when the system is open.
  • Wiring terminations should not be made with the product and/or electric lines under power.
  • Product installation and/or mounting should be completed by a certified professional as per the local safety and building code guidelines.
  • Cables (including power and charging cables) should be placed and routed to avoid creating electric, tripping or safety hazards.
* Produkters utseende och specifikationer kan komma att ändras utan förvarning.
Vänta...
Tillbaka till toppen